1994
DOI: 10.1002/hbm.460010206
|View full text |Cite
|
Sign up to set email alerts
|

Spatiotemporal analysis of brain electrical fields

Abstract: Psychological studies with reaction time methodology show that there is meaningful variability in the performance of cognitive operations when responses are measured in milliseconds. Temporal precision is also required to reveal the rapid neurophysiological events in cortical networks. Sampling the brain's electrical activity at the scalp surface characterizes regional brain function with millisecond temporal resolution. The problem with electroencephalographic (EEG) data is localizing the areas of the cortex … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
118
0

Year Published

1998
1998
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 213 publications
(121 citation statements)
references
References 35 publications
3
118
0
Order By: Relevance
“…Individual bad channels were replaced on a trial-by-trial basis according to a spherical spline algorithm (Srinivasan, Nunez, Silberstein, Tucker, & Cadusch, 1996). EEG was measured with respect to a vertex reference (Cz), but an average-reference transformation was used to minimize the effects of reference-site activity and to estimate accurately the scalp topography of the measured electrical fields (Bertrand, Perin, & Pernier, 1985;Curran, Tucker, Kutas, & Posner, 1993;Dien, 1998;Lehman & Skrandies, 1985;Picton, Lins, & Scherg, 1995;Tucker, Liotti, Potts, Russell, & Posner, 1994). Average-reference ERPs were computed for each channel as the voltage difference between that channel and the average of all channels.…”
Section: Eeg/erp Methodsmentioning
confidence: 99%
“…Individual bad channels were replaced on a trial-by-trial basis according to a spherical spline algorithm (Srinivasan, Nunez, Silberstein, Tucker, & Cadusch, 1996). EEG was measured with respect to a vertex reference (Cz), but an average-reference transformation was used to minimize the effects of reference-site activity and to estimate accurately the scalp topography of the measured electrical fields (Bertrand, Perin, & Pernier, 1985;Curran, Tucker, Kutas, & Posner, 1993;Dien, 1998;Lehman & Skrandies, 1985;Picton, Lins, & Scherg, 1995;Tucker, Liotti, Potts, Russell, & Posner, 1994). Average-reference ERPs were computed for each channel as the voltage difference between that channel and the average of all channels.…”
Section: Eeg/erp Methodsmentioning
confidence: 99%
“…EEG was measured with respect to a vertex reference (Cz), but an average reference transformation was used to minimize the effects of reference site activity and accurately estimate the scalp topography of the measured electrical fields (Bertrand, Perin, & Pernier, 1985;Curran, Tucker, Kutas, & Posner, 1993;Dien, 1998;Lehman & Skrandies, 1985;Picton, Lins, & Scherg, 1995;Tucker, Liotti, Potts, Russell, & Posner, 1994). Average reference ERPs are computed for each channel as the voltage difference between that channel and the average of all the channels.…”
Section: Eeg/erp Methodsmentioning
confidence: 99%
“…A baseline correction on the prestimulus interval (-100/0 ms) was computed on each individual epoch prior to averaging. Averaged ERPs were rereferenced offline using a common average-reference [Tucker et al, 1994]. Data were low-pass filtered at 30 Hz.…”
Section: Data Acquisitionmentioning
confidence: 99%