Spectrophotometric determination of phenol in the presence of congeners by multivariated calibration

Abstract: The generation of poly-hydroxilated transient species during the photochemical treatment of phenol usually impedes the spectrophotmetric monitoring of its degradation process. Frequently, the appearance of compounds such as pyrocatechol, hydroquinone and benzoquinone produces serious spectral interference, which hinder the use of the classical univariate calibration process. In this work, the use of multivariate calibration is proposed to permit the spectrophotometric determination of phenol in the presence of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
4
0

Year Published

2006
2006
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 6 publications
1
4
0
Order By: Relevance
“…In the UV region absorbance, phenol has two broad peak bands between 200 and 235 nm, and again two peaks on a band at around 270-280 nm. These values correspond broadly with literature values for phenol absorbance at around 235 and 275 nm [33][34][35]. As the phenol concentration in the water decreased, the absorbance peaks in the former band shifts to even lower wavelengths ( Figure 5), which can be attributed probably to the decrease of the peak height at the higher wavelength.…”
Section: Performance Of the Spectrophotometric Proceduressupporting
confidence: 90%
See 1 more Smart Citation
“…In the UV region absorbance, phenol has two broad peak bands between 200 and 235 nm, and again two peaks on a band at around 270-280 nm. These values correspond broadly with literature values for phenol absorbance at around 235 and 275 nm [33][34][35]. As the phenol concentration in the water decreased, the absorbance peaks in the former band shifts to even lower wavelengths ( Figure 5), which can be attributed probably to the decrease of the peak height at the higher wavelength.…”
Section: Performance Of the Spectrophotometric Proceduressupporting
confidence: 90%
“…With appropriate mathematical models applied to the analytical data, the model parameters can be obtained to estimate the concentration in the samples. Among those, linear regression, partial least squares regression and principal components regression have been used with success in complex determinations [34,[36][37][38][39].…”
Section: Performance Of the Spectrophotometric Proceduresmentioning
confidence: 99%
“…As aromatic compounds absorb light at UV wavelength, absorbance spectra were also realized between 240 and 300 nm. The absorbance peaks were then integrated to determine relative concentrations of aromatic compounds (from aPW) [31][32][33][34]. For NH 4 + , COD, and aromatic compounds, the relative removal percentages were then calculated in each sample as the difference between the concentrations on day 0 and days 7, 14, and 23.…”
Section: Dissolved Compounds Monitoringmentioning
confidence: 99%
“…A number of analytical methods are reported for the determination of phenols, based on spectrophotometric, fluorimetric, kinetic, gas chromatographic, liquid chromatographic and enzyme and biosensors. Due to several characteristic features such as high sensitivity, operational facility and low cost the UV-visible spectroscopy is one of the most useful analytical techniques 9 .…”
Section: Introductionmentioning
confidence: 99%