“…29 Si solid-state CP/MAS NMR spectra were measured on a Bruker AV 400 MHz spectrometer. Powder X-ray diffraction patterns were recorded on a D/max-IIIA Rigaku diffractometer with Cu anode.…”
Section: Characterization Methods and Optical Measurementsmentioning
confidence: 99%
“…For this experiment, special care was taken to keep constant the illuminated surface of sample and the power of the incident UV light. 29 Si solid-state CP/MAS NMR spectra of MCM-48 and MCM-48-R were recorded in order to check the successful grafting of MTES and AAPTMS groups. Representative spectra are presented in Fig.…”
Section: Characterization Methods and Optical Measurementsmentioning
confidence: 99%
“…Site selective spectra were also recorded at low temperature (15 K) by exciting selectively the 5 D 0 or the 5 D 2 levels of Eu (III), but at the exception of Eu(DBM) 3 Á H 2 O, these spectra did not provide any additional information on the Stark structure of the 7 F J components due to inhomogeneous broadening. Judd-Ofelt's experimental intensity parameters O 2,4 were calculated from the room temperature emission spectra following a procedure reported in several papers [29][30][31][32][33]. The values are given in Table 3.…”
“…29 Si solid-state CP/MAS NMR spectra were measured on a Bruker AV 400 MHz spectrometer. Powder X-ray diffraction patterns were recorded on a D/max-IIIA Rigaku diffractometer with Cu anode.…”
Section: Characterization Methods and Optical Measurementsmentioning
confidence: 99%
“…For this experiment, special care was taken to keep constant the illuminated surface of sample and the power of the incident UV light. 29 Si solid-state CP/MAS NMR spectra of MCM-48 and MCM-48-R were recorded in order to check the successful grafting of MTES and AAPTMS groups. Representative spectra are presented in Fig.…”
Section: Characterization Methods and Optical Measurementsmentioning
confidence: 99%
“…Site selective spectra were also recorded at low temperature (15 K) by exciting selectively the 5 D 0 or the 5 D 2 levels of Eu (III), but at the exception of Eu(DBM) 3 Á H 2 O, these spectra did not provide any additional information on the Stark structure of the 7 F J components due to inhomogeneous broadening. Judd-Ofelt's experimental intensity parameters O 2,4 were calculated from the room temperature emission spectra following a procedure reported in several papers [29][30][31][32][33]. The values are given in Table 3.…”
“…The A 0j rates (see Eq. (1)) are calculated from the integrated intensity ratios between the 5 D 0 → 7 F j and 5 D 0 → 7 F 1 emission transitions and the value of magnetic-dipole transition rate A 01 is estimated to be 50 s −1 [26].…”
Section: Radiative Properties Emission Quantum Efficiency and Judd-omentioning
“…To better understand the effect of chelation on spectroscopic prosperities of Eu 3+ , Judd-Ofelt's experimental intensity parameters O 2 and O 4 were calculated from emission spectra at room temperature by using the following equation [15][16][17][18].…”
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.