2002
DOI: 10.1007/s00404-001-0281-4
|View full text |Cite
|
Sign up to set email alerts
|

Spinal anesthesia hypotension in elective cesarean section in parturients wearing extra-strong compression stockings

Abstract: We have routinely applied an extra-strong graduated compression stocking to cesarean section patients to reduce the incidence of spinal anesthesia hypotension. Because bupivacaine has recently become available in Japan, we compared the incidence of spinal hypotension using either 2.0 ml of hyperbaric 0.3% dibucaine or 0.5% bupivacaine. There were 98 full-term parturients wearing the stocking who received 2.0 ml injection of dibucaine or bupivacaine for elective cesarean section. When systolic blood pressure de… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0

Year Published

2004
2004
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(2 citation statements)
references
References 22 publications
0
1
0
Order By: Relevance
“…Cephalad placement at 7 cm is our regimen to prevent catheter migration from the epidural space [15]. Thereafter, 8 to 10 mL of 1% ropivacaine was injected epidurally according to our formula for estimating anesthetic spread [16], which was then confirmed by ice packed in a surgical glove that also is our routine regimen [17,18]. The patient was given general anesthesia using propofol alone according to our anesthetic protocol [19][20][21].…”
Section: Methodsmentioning
confidence: 99%
“…Cephalad placement at 7 cm is our regimen to prevent catheter migration from the epidural space [15]. Thereafter, 8 to 10 mL of 1% ropivacaine was injected epidurally according to our formula for estimating anesthetic spread [16], which was then confirmed by ice packed in a surgical glove that also is our routine regimen [17,18]. The patient was given general anesthesia using propofol alone according to our anesthetic protocol [19][20][21].…”
Section: Methodsmentioning
confidence: 99%
“…It occurs in 80-85% of pregnant women after spinal anaesthesia and presents with symptoms of nausea, vomiting or apprehension. 7,8 Preloading with crystalloids, use of inotropic agents (Ephedrine and phenylephrine etc. ), prevention of aortocaval compression, use of compression stockings, and initial frequent blood pressure monitoring prevent hemodynamic instability.…”
Section: Introductionmentioning
confidence: 99%