Stability of carboplatin in 5% glucose solution exposed to light

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

1997
1997
2014
2014

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 4 publications
0
5
0
Order By: Relevance
“…In addition, the stability of these new platinum compounds in solution was explored, since many differences in the action of cisplatin and second-generation compounds have been found, depending on the test conditions, such as light and solvent. [17][18][19][20][21][22][23][24][25][26][27] The present contribution describes the synthesis, crystal structure, and solution behavior of these two new fluorescent platinum(II) compounds in DMSO. In addition, the cytotoxic activity of both platinum(II) compounds and their corresponding carrier ligands was measured in human tumor cell lines, including human ovarian carcinoma cell line A2780 and its cisplatin-resistant counterpart A2780R.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, the stability of these new platinum compounds in solution was explored, since many differences in the action of cisplatin and second-generation compounds have been found, depending on the test conditions, such as light and solvent. [17][18][19][20][21][22][23][24][25][26][27] The present contribution describes the synthesis, crystal structure, and solution behavior of these two new fluorescent platinum(II) compounds in DMSO. In addition, the cytotoxic activity of both platinum(II) compounds and their corresponding carrier ligands was measured in human tumor cell lines, including human ovarian carcinoma cell line A2780 and its cisplatin-resistant counterpart A2780R.…”
Section: Introductionmentioning
confidence: 99%
“…Because the carrier ligand A9opy is coordinated to the platinum(II) ion through the isomerizable carbon−carbon double bond in compound 1 , the study of such a compound in solution, and the influence of the light in its stability toward isomerization of the coordinated carbon−carbon double bond, was undertaken and performed by NMR spectroscopy. In addition, the stability of these new platinum compounds in solution was explored, since many differences in the action of cisplatin and second-generation compounds have been found, depending on the test conditions, such as light and solvent. The present contribution describes the synthesis, crystal structure, and solution behavior of these two new fluorescent platinum(II) compounds in DMSO. In addition, the cytotoxic activity of both platinum(II) compounds and their corresponding carrier ligands was measured in human tumor cell lines, including human ovarian carcinoma cell line A2780 and its cisplatin-resistant counterpart A2780R.…”
Section: Introductionmentioning
confidence: 99%
“…14,22,37,38 For instance, Torres et al 22 found that in 0.8 mg/mL and 3.2 mg/mL solutions of carboplatin-5% glucose exposed to light, 10% degradation occurred within 1-10 h depending on light intensity. 22 Similarly, Pujol et al 38 found that carboplatin Table 1. Chemical stability of carboplatin 0.5 mg/mL, 2.0 mg/mL, and 4.0 mg/mL solutions prepared in 0.9% sodium chloride in PVC bags.…”
Section: Discussionmentioning
confidence: 99%
“…11,12 Accordingly, the final diluted infusion solutions are stable up to 8 h at 25 C. 11,12 Currently, there is an abundance of stability data on carboplatin solutions prepared in D5W. [13][14][15][16][17][18][19][20][21][22] Many of these studies have been reviewed elsewhere, 23 and a comprehensive review of the data is beyond the scope of this manuscript. In brief, the stability of carboplatin-D5W infusion solutions stored at room temperature ($25 C) ranges from 1 day to 30 days in various administration packages.…”
Section: Introductionmentioning
confidence: 99%
“…However, illuminance under ordinary ‰uorescent lamps is about 0.2 1.0 kLux, diŠer-ing considerably from outdoor illuminance (under a roof) value of 48.82±6.01 kLux used in the present study. Torres et al 3) showed that stabilities was dened as <10% loss of initial drug concentration when the samples were exposed under diŠerent illumination conditions. Carballar et al 4) demonstrated a degradation of >50% of initial condition under 105, 143, and >200 kLx with a 250 W Xe lamp.…”
Section: Discussionmentioning
confidence: 99%