Standardization of an external (in air) PIGE methodology using tantalum as a current normalizer in conjunction with INAA for rapid and non-destructive chemical characterization of “as-received” glass fragments towards forensic applications

Abstract: Rapid automobile glass forensics by non-destructive analysis of “as-received” samples by external (in-air) PIGE for low Z elements with tantalum as a current normalizer and INAA for minor and trace elements using reactor neutrons.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
28
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 22 publications
(29 citation statements)
references
References 42 publications
1
28
0
Order By: Relevance
“…However, our laboratory has come up with simple current normalization methods like the in situ method (constant amount of Li or F added in the sample), 17 and external use of prompt γ-rays (165 keV) from the tantalum window. 22 In the present work, prompt γ-ray peak (2312 keV) from nuclear reaction ( 14 N(p,p′γ) 14 N) has been proposed as a new method for current normalization. Earlier, both the nuclear reactions 14 N(p,p′γ) 14 N ( E γ = 2312 keV) and 15 N(p,αγ) 12 C ( E γ = 4439 keV) have been utilized for determination of nitrogen in blood serum samples by PIGE method.…”
Section: Experimental and Calculation Detailsmentioning
confidence: 99%
See 2 more Smart Citations
“…However, our laboratory has come up with simple current normalization methods like the in situ method (constant amount of Li or F added in the sample), 17 and external use of prompt γ-rays (165 keV) from the tantalum window. 22 In the present work, prompt γ-ray peak (2312 keV) from nuclear reaction ( 14 N(p,p′γ) 14 N) has been proposed as a new method for current normalization. Earlier, both the nuclear reactions 14 N(p,p′γ) 14 N ( E γ = 2312 keV) and 15 N(p,αγ) 12 C ( E γ = 4439 keV) have been utilized for determination of nitrogen in blood serum samples by PIGE method.…”
Section: Experimental and Calculation Detailsmentioning
confidence: 99%
“…Conventional PIGE methods were utilized in our laboratory using in situ current normalization/current normalization from the Tantalum window for uorine determination in coal, soil, and several geological samples. [20][21][22] In the course of time, the external (in air) PIGE method has also been developed by researchers, thereby making the method simpler, rapid, and promising for analyzing samples with non-standard geometry. [23][24][25][26] Current normalization is always a challenging task in PIGE.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…A standardized method for the in- air particle induced gamma-ray emission (PIGE) analysis of glass fragments that uses a tantalum window material as a current normaliser was reported in a paper by Sharma et al 132 Glass fragments were irradiated in air using a 3.5 MeV proton beam and simultaneous measurement of the prompt gamma rays from proton-induced reactions of isotopes of low atomic number elements e.g. Al, B, Mg, Na and Si as well as those at 135 or 165 keV from the tantalum window were measured.…”
Section: Inorganic Chemicals and Materialsmentioning
confidence: 99%
“…27 Recently, the use of prompt gamma rays from a tantalum window was proposed for beam current normalization, and this set-up was successfully used at folded tandem ion accelerator (FOTIA), BARC, Mumbai. 28…”
Section: Introductionmentioning
confidence: 99%