2021
DOI: 10.1016/j.cofs.2021.08.002
|View full text |Cite
|
Sign up to set email alerts
|

Static and semi-dynamic in vitro digestion methods: state of the art and recent achievements towards standardization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 31 publications
(18 citation statements)
references
References 35 publications
0
14
0
Order By: Relevance
“…Then, the current review discusses important strategic considerations for setting up IVD experiments. Recent reviews on IVD approaches have been focusing on one specific macronutrient, food type, specific population group, or deliver a descriptive overview of the current state of the art (Shani- Calvo-Lerma et al, 2018;Sensoy, 2021;Xavier and Mariutti, 2021). However, an integrated overview of the recent progress and evolution in the context of food science and technology and specifically food structural design is still missing.…”
Section: Introductionmentioning
confidence: 99%
“…Then, the current review discusses important strategic considerations for setting up IVD experiments. Recent reviews on IVD approaches have been focusing on one specific macronutrient, food type, specific population group, or deliver a descriptive overview of the current state of the art (Shani- Calvo-Lerma et al, 2018;Sensoy, 2021;Xavier and Mariutti, 2021). However, an integrated overview of the recent progress and evolution in the context of food science and technology and specifically food structural design is still missing.…”
Section: Introductionmentioning
confidence: 99%
“…However, all average parameters (e.g., pH value) are set at the beginning of the experiment, the dynamic release of enzymes is not feasible, the accumulation of metabolites is not considered, and the complex physiology of the digestive tract is not imitated. Therefore, there is a need for further research using dynamic in vitro digestion protocols in order to come as close as possible to what occurs in vivo [87]. Taking into account the advantages and disadvantages mentioned here, only static systems will be used for discussion in the following section.…”
Section: Stability In Simulated Gastric Fluid and Release In Simulate...mentioning
confidence: 99%
“…To offset the technical limitations of the static in vitro digestion models associated with the dynamics of the physiology of digestion [ 32 ], the gastric fluids were added at a constant rate and under constant stirring to achieve the target gastric pH gastric = 2.5 within 5 min (t = 0 min). The enzymatic activity of pepsin was predetermined, and the amount of the HCl required for achieving the pH gastric = 2.5 was customised per food model to minimise the buffering effect of the milk proteins and FG.…”
Section: Resultsmentioning
confidence: 99%