2019
DOI: 10.1080/19392699.2019.1622530
|View full text |Cite
|
Sign up to set email alerts
|

Statistical analysis of Egyptian oil shale column flotation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 18 publications
0
3
0
Order By: Relevance
“…The interaction between the activator and depressant dosages positively affected the separation efficiency. This is because the depressant and activator dosages significantly effectively depress the iron oxide particles and activate the quartz particles respectively for an efficient flotation process by the anionic collector at 11.5 pH value since the flotation technique relies on the enhanced capture of hydrophobic minerals by micro-bubbles, while the hydrophilic minerals settle down to the tailings stream (Laplante et al, 1993;Sobhy et al, 2019). Furthermore, the depressant dosage showed major influences on the separation efficiency in comparison with the activator dosage.…”
Section: Factors Combined Effects and Optimizationmentioning
confidence: 99%
“…The interaction between the activator and depressant dosages positively affected the separation efficiency. This is because the depressant and activator dosages significantly effectively depress the iron oxide particles and activate the quartz particles respectively for an efficient flotation process by the anionic collector at 11.5 pH value since the flotation technique relies on the enhanced capture of hydrophobic minerals by micro-bubbles, while the hydrophilic minerals settle down to the tailings stream (Laplante et al, 1993;Sobhy et al, 2019). Furthermore, the depressant dosage showed major influences on the separation efficiency in comparison with the activator dosage.…”
Section: Factors Combined Effects and Optimizationmentioning
confidence: 99%
“…e Z-test has the limitation that it is applied when the sample size is greater than thirty. e authors of [1][2][3][4] and [5] worked on the applications of statistical tests.…”
Section: Introductionmentioning
confidence: 99%
“…A concentrate of 42% kerogen with 94% recovery was produced using Falcon SB40 concentrator at 60 Hz and water pressure of 4 Psi (Yehia et al, 2017). A concentrate of 38% kerogen with 88.5% recovery was obtained using column flotation in presence of kerosene as a collector and MIBC as a frother (Sobhy et al, 2019).…”
Section: Introductionmentioning
confidence: 99%