2014
DOI: 10.3109/14992027.2014.979300
|View full text |Cite
|
Sign up to set email alerts
|

Stimulus and transducer effects on threshold

Abstract: Objective This study examined differences in thresholds obtained under Sennheiser HDA200 circumaural earphones using pure tone, equivalent rectangular noise bands, and 1/3 octave noise bands relative to thresholds obtained using Telephonics TDH-39P supra-aural earphones. Design Thresholds were obtained via each transducer and stimulus condition six times within a 10-day period. Study Sample Forty-nine adults were selected from a prior study to represent low, moderate, and high threshold reliability. Resu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
3
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 8 publications
2
3
0
Order By: Relevance
“…The standard deviations at 750, 1,500, and 3,000 Hz were 3.7, 5.2, and 4.3 dB, respectively. This is in close agreement with the standard deviations reported for clinical audiometry [Flamme et al, 2015]. The correlation coefficients were 0.91, 0.76, and 0.87, respectively.…”
Section: Differences Between Testssupporting
confidence: 80%
“…The standard deviations at 750, 1,500, and 3,000 Hz were 3.7, 5.2, and 4.3 dB, respectively. This is in close agreement with the standard deviations reported for clinical audiometry [Flamme et al, 2015]. The correlation coefficients were 0.91, 0.76, and 0.87, respectively.…”
Section: Differences Between Testssupporting
confidence: 80%
“…In our study, the mean interparticipant differences between conventional and in-situ audiometry were within ± 5 dB for all tested hearing aids across frequencies of 250–6000 Hz, which are crucial frequencies for speech. This 5 dB error is clinically acceptable, consistent with the expected measurement error using the Hughson-Westlake 5-up 10-down procedure, and is in agreement with deviations reported for clinical audiometry ( Flamme et al, 2015 ).…”
Section: Discussionsupporting
confidence: 89%
“…Given the possibility of using supra-aural, insert, or circumaural earphones to obtain air-conduction hearing thresholds at 250 to 8000 Hz, we must compare them and verify the users' satisfaction with them. We commonly find studies reporting the difference in hearing thresholds obtained with supra-aural and insert earphones in different populations (5,6,(8)(9)(10)(11)(12) , whereas comparisons with circumaural earphones are still scarce (6,17) .…”
Section: Discussionmentioning
confidence: 99%