A large portion of the general population is exposed to noise levels that could result in long-term adverse effects on hearing. Gender and occupation were most strongly related to exposure, though most participants in this study had occupations that are not conventionally considered noisy.
Objective To estimate the short-term variability and correlates of variability in pure-tone thresholds obtained using audiometric equipment designed for occupational use, and to examine the justification for excluding 8 kHz as a mandatory threshold in occupational hearing conservation programs. Method Pure-tone thresholds and other hearing-related tests (e.g., noise dosimetry, otoscopy, middle ear assessment) were conducted with a group of 527 adults between 20 and 69 years of age. A total of five measurement visits were completed by participants within a 14-day period. Results The 50 % critical difference boundaries were −5 and 0 dB at 4 kHz and below and −5 and 5 dB at 6 and 8 kHz. The likelihood of spurious notches due to test-retest variability was substantially lower than the likelihood of failing to detect a notched configuration when present. Correlates of variability included stimulus frequency, baseline threshold, acoustic reflectance of the ear, average noise exposure during the previous 8 hours, age, and the tester’s level of education in audiology. Conclusion The short-term variability in 8 kHz pure tone thresholds obtained with the TDH-39P earphone was slightly greater than at other frequencies, but this difference was not large enough to justify the disadvantages stemming from the inability to detect a 6 kHz notch.
Acoustic reflexes are common among individuals with good hearing. However, acoustic reflexes are not pervasive and should not be included in damage risk criteria and health hazard assessments for impulsive noise.
Objective This study examined differences in thresholds obtained under Sennheiser HDA200 circumaural earphones using pure tone, equivalent rectangular noise bands, and 1/3 octave noise bands relative to thresholds obtained using Telephonics TDH-39P supra-aural earphones. Design Thresholds were obtained via each transducer and stimulus condition six times within a 10-day period. Study Sample Forty-nine adults were selected from a prior study to represent low, moderate, and high threshold reliability. Results The results suggested that (1) only small adjustments were needed to reach equivalent TDH-39P thresholds, (2) pure-tone thresholds obtained with HDA200 circumaural earphones had reliability equal to or better than those obtained using TDH-39P earphones, (3) the reliability of noise-band thresholds improved with broader stimulus bandwidth and was either equal to or better than pure-tone thresholds, and (4) frequency-specificity declined with stimulus bandwidths greater than one Equivalent Rectangular Band, which could complicate early detection of hearing changes that occur within a narrow frequency range. Conclusions These data suggest that circumaural earphones such as the HDA200 headphones provide better reliability for audiometric testing as compared to the TDH-39P earphones. These data support the use of noise bands, preferably ERB noises, as stimuli for audiometric monitoring.
Otoacoustic emissions (OAEs) are generated in the cochlea in response to sound and are used clinically to separate ears with normal hearing from sensorineural hearing loss (SNHL). OAEs were elicited at ambient pressure by clicks (CEOAE) and wideband chirps (TEOAE) sweeping from low-to-high frequency with a sweep rate of either 187.6 Hz/ms (short chirps) or 58.2 Hz/ms (long chirps) and a bandwidth extending to 8 kHz. Chirps were presented at the same sound exposure level (SEL) as clicks, or + 6 dB relative to clicks. A total of 288 OAE waveforms were averaged for short chirps in ~1 minute compared to 120 waveforms for long chirps. Compared to clicks, the chirp has a lower crest factor, which allows it to be presented at an overall higher SEL without distortion. OAEs were elicited in 79 adults with normal hearing and 51 adults with mild-to-moderate SNHL. One-sixth octave OAE signal-to-noise ratios from 0.7 to 8.0 kHz were compared across stimulus types and conditions. The area under the receiver operating curve (AUC) was used to assess the accuracy of detecting SNHL. Average AUCs across 1/6th octave frequencies ranged from 0.90 to 0.89 for TEOAEs and were 0.87 for the CEOAE suggesting excellent test performance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.