2022
DOI: 10.3390/brainsci12121606
|View full text |Cite
|
Sign up to set email alerts
|

STN-DBS Induces Acute Changes in β-Band Cortical Functional Connectivity in Patients with Parkinson’s Disease

Abstract: Subthalamic nucleus deep-brain stimulation (STN-DBS), in addition to a rapid improvement of Parkinson’s disease (PD) motor symptoms, can exert fast, local, neuromodulator activity, reducing β-synchronous oscillations between STN and the motor cortex with possible antikinetic features. However, STN-DBS modulation of β-band synchronization in extramotor cortical areas has been scarcely explored. For this aim, we investigated DBS-induced short-term effects on EEG-based cortical functional connectivity (FC) in β b… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 37 publications
0
6
0
Order By: Relevance
“…Independent component analysis was used to remove the residual EEG artifacts 26 . Then, we proceeded with EEG source localization 17 …”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Independent component analysis was used to remove the residual EEG artifacts 26 . Then, we proceeded with EEG source localization 17 …”
Section: Methodsmentioning
confidence: 99%
“…HD-EEG, a non-invasive and accessible method to evaluate cortical electrical activity, overcomes the limitations, as it can detect subtle dysfunctions in cortical processing with high temporal resolution. 16,17 We hypothesized that the OBTA treatment could induce functional modification in patients with CM. The primary aim of this pilot study was to provide novel insights into the central mechanisms of action of OBTA in CM treatment.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Independent component analysis (ICA) was used to remove the residual EEG artifacts 35 . We proceeded with EEG source localization 36 . All study subjects underwent MRI, performed on a 3 T system (Achieva, Philips Medical Systems), with an eight‐channel phased array head coil.…”
Section: Methodsmentioning
confidence: 99%
“…35 We proceeded with EEG source localization. 36 All study subjects underwent MRI, performed on a 3 T system (Achieva, Philips Medical Systems), with an eight-channel phased array head coil. The head model and the cortex surface were computed for each subject based on personal MRI, using CAT12 software (parameters: vertices on the cortex surface 15 000, cortical thickness 12 mm, folding measures 20 mm).…”
Section: Fc Analysismentioning
confidence: 99%