Strain-Encoded CMR for the Detection of Inducible Ischemia During Intermediate Stress

Abstract: Using SENC, CAD can be detected during intermediate stress with similar accuracy to that provided by cine only during peak stress. By this approach, patient safety may be improved during diagnostic procedures within lower time spent (Strain-Encoded Cardiac Magnetic Resonance Imaging for Dobutamine Stress Testing; NCT00758654).

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
69
1

Year Published

2011
2011
2023
2023

Publication Types

Select...
4
1
1

Relationship

2
4

Authors

Journals

citations
Cited by 73 publications
(74 citation statements)
references
References 21 publications
4
69
1
Order By: Relevance
“…A number of different parameters derived from the SR 22 signal have been proposed, 66,109 and the value of the negative peak between aortic valve opening and closing has been used the most often. 66,[86][87][88]94 The sensitivity of Peak SR 22 to demand ischemia has been shown to be limited in some studies in vivo, 66,94 which is consistent with our model results. The measurement of strain rate with speckle tracking has become more common, making measurement of Peak SR 11 feasible clinically, and this model indicates that using Peak SR 11 may be better for detecting abnormal function.…”
Section: Comparison To Previous Studiessupporting
confidence: 89%
See 4 more Smart Citations
“…A number of different parameters derived from the SR 22 signal have been proposed, 66,109 and the value of the negative peak between aortic valve opening and closing has been used the most often. 66,[86][87][88]94 The sensitivity of Peak SR 22 to demand ischemia has been shown to be limited in some studies in vivo, 66,94 which is consistent with our model results. The measurement of strain rate with speckle tracking has become more common, making measurement of Peak SR 11 feasible clinically, and this model indicates that using Peak SR 11 may be better for detecting abnormal function.…”
Section: Comparison To Previous Studiessupporting
confidence: 89%
“…Previous studies have shown conflicting results in comparing circumferential and longitudinal strain for diagnosis of dobutamine-induced ischemia; some studies show circumferential strain to be superior to longitudinal, 93 while others claim they are diagnostically equivalent. 65,94 Longitudinal strain was often used in the past because it was easier to measure with tissue Doppler imaging than circumferential strain. A detailed study of strains measured with radiopaque beads in dogs during brief coronary occlusion at rest showed that the amount of endocardial and midwall dyskinesis after 5 minutes of ischemia is similar in the longitudinal and circumferential directions, and the change in endocardial strain from control to ischemia was 0.19 ± 0.08 in the circumferential direction and 0.16 ± 0.06 in the longitudinal direction.…”
Section: Strain Analysismentioning
confidence: 99%