2016
DOI: 10.1016/j.neuroimage.2015.09.047
|View full text |Cite
|
Sign up to set email alerts
|

Stratified mixture modeling for segmentation of white-matter lesions in brain MR images

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
16
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 20 publications
(16 citation statements)
references
References 54 publications
0
16
0
Order By: Relevance
“…Other clinical images, such as T2-weighted or proton density, may be also used in our multi-channel approach, although the hyper parameters require to be tuned accordingly. Most MS lesion segmentation methods reported in the literature show low performance when applied to patient data exhibiting low lesion load and small lesions ( Anbeek et al, 2004 ; Cabezas et al, 2014 ; Galimzianova et al, 2016 ; Sajja et al, 2006 ; Schmidt et al, 2012 ; Steenwijk et al, 2013 ). However, accurate detection especially in the early stages of MS can be crucial for initial diagnosis and subsequent treatment monitoring ( Filippi et al, 2016 ).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Other clinical images, such as T2-weighted or proton density, may be also used in our multi-channel approach, although the hyper parameters require to be tuned accordingly. Most MS lesion segmentation methods reported in the literature show low performance when applied to patient data exhibiting low lesion load and small lesions ( Anbeek et al, 2004 ; Cabezas et al, 2014 ; Galimzianova et al, 2016 ; Sajja et al, 2006 ; Schmidt et al, 2012 ; Steenwijk et al, 2013 ). However, accurate detection especially in the early stages of MS can be crucial for initial diagnosis and subsequent treatment monitoring ( Filippi et al, 2016 ).…”
Section: Discussionmentioning
confidence: 99%
“…DSC is one of the most commonly-used metrics to measure the segmentation quality ( Lladó, Oliver, et al, 2012 ); however, this metric is not appropriate to evaluate the segmentation of small objects ( Schmidt et al, 2012 ). Despite this, DSC is widely used ( Brosch et al, 2016 ; Galimzianova et al, 2016 ; Jain et al, 2015 ) even to this type of data characterized with low lesion load. Interestingly, the median of DSC for the PV-method was significantly higher than for the other two studied methods.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Moreover, most proposed methods have been validated on a restricted number of cases and within single centers or simulated MR imaging acquisitions. 5,17,18 In addition, a validation of the method based on data provided by the MICCAI Grand Challenge workshop 2008 would be unfeasible because of the absence of a DE sequence in the dataset. 6,19 In this study, a validation of the method against manual segmentation in a multicenter context was presented, proving that the method was robust to scanner differences and that its performance was not dependent on MR software and hardware.…”
Section: Discussionmentioning
confidence: 99%
“…Magnetic Resonance Imaging (MRI) as non-invasive and most widely used medical imaging modality is paramount for accurate anatomical analysis of human's internal brain layers [1]- [3]. With Radio Frequency (RF) pulses generated in MRI, the subjects T1 and T2 weighted Magnetic Resonance (MR) images are acquired [4].…”
Section: Introductionmentioning
confidence: 99%