2011
DOI: 10.4061/2011/269452
|View full text |Cite
|
Sign up to set email alerts
|

Stripping Voltammetric Determination of Analgesics in Their Pharmaceuticals Using Nano-Riboflavin-Modified Glassy Carbon Electrode

Abstract: Cyclic voltammetric behaviors of three analgesics, acetaminophen (AAP), acetylsalicylic acid (ASA), and dipyrone (DP), were studied using nano-riboflavin-modified glassy carbon electrode. One well-defined oxidation peak each for AAP and ASA and three oxidation peaks for DP were observed. The influence of pH, scan rate, and concentration reveals irreversible diffusion controlled reaction. The SEM analysis confirmed good accumulation of the drugs on the electrode surface. Calibration was made under the maximum p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
14
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(14 citation statements)
references
References 41 publications
0
14
0
Order By: Relevance
“…Higher sensitivities were obtained in [12,14], but with narrower linear ranges. Detection limits were similar to those in [12] and much lower than in [9]; although they were higher than those in [13,42,43] ( [13,43] using stripping voltammetric techniques), in these cases, the upper linear range limits were only 2.6 μM [13,43] and 16 μM [42].…”
Section: Dipyrone Determinationmentioning
confidence: 71%
“…Higher sensitivities were obtained in [12,14], but with narrower linear ranges. Detection limits were similar to those in [12] and much lower than in [9]; although they were higher than those in [13,42,43] ( [13,43] using stripping voltammetric techniques), in these cases, the upper linear range limits were only 2.6 μM [13,43] and 16 μM [42].…”
Section: Dipyrone Determinationmentioning
confidence: 71%
“…19,20 In practical cases, the slope values lying between 0.20-0.60 and 0.75-1.10 are considered pure diffusion and pure adsorption controlled processes, respectively. 21,22 The slope lying between 0.60-0.75 is considered a mixed adsorption-diffusion controlled process. 21,22 The plots of log?Ip?…”
Section: Prepartion Of Polyaniline (Pani) Modified Platinum Electrode...mentioning
confidence: 99%
“…21,22 The slope lying between 0.60-0.75 is considered a mixed adsorption-diffusion controlled process. 21,22 The plots of log?Ip? versus log (n) for both the cathodic and anodic peaks yield straight lines of gradients 0.33 (R 2 = 0.994) and 0.35 (R 2 = 0.987), respectively.…”
Section: Prepartion Of Polyaniline (Pani) Modified Platinum Electrode...mentioning
confidence: 99%
“…Cyclic voltammetry is now used as a technique for studying the redox potential of different types of drugs. By using this technique, it is also possible to establish an irreversible controlled diffusion-reaction by monitoring the effects of pH, scan rate and concentration [12].…”
Section: Introductionmentioning
confidence: 99%