2021
DOI: 10.37373/jttm.v2i2.124
|View full text |Cite
|
Sign up to set email alerts
|

Studi Evaluasi Keselamatan Pada LPG Storage Tank Berdasarkan Tingkat Risiko Menggunakan Metode Risk Based Inspection

Abstract: Analisis risiko merupakan hal yang sangat penting dalam dunia industri baik itu industri manufaktur, power plant, petrokimia, obat-obatan dan tidak terkecuali dengan industri minyak dan gas bumi karena hal tersebut berkaitan dengan keselamatan dan keamanan. Dalam penelitian ini suatu analisis risiko telah lakukan pada suatu bejana tekan (pressure vessel) yang difungsikan sebagai LPG Storage Tank berkapasitas 50 Ton dan telah dipergunakan selama 10 tahun, tujuan dalam penelitian ini adalah untuk mendapatkan inf… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
0
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 6 publications
0
0
0
Order By: Relevance
“…Corrosion monitoring The corrosion monitoring technique attempts to determine the corrosion rate of a metal so that the corrosion rate may be used to predict when and how long the workpiece can be used [12]. Analysis of corrosion rate and remaining life in roll-off tanks using the Corrosion Monitoring method with the Non-Destructive Test (NDT) approach with visual inspection following the ASME VIII Div 1 standard, namely by making comparisons between roll-off tank design data and actual technical data regarding roll-off tank.…”
Section: 1mentioning
confidence: 99%
“…Corrosion monitoring The corrosion monitoring technique attempts to determine the corrosion rate of a metal so that the corrosion rate may be used to predict when and how long the workpiece can be used [12]. Analysis of corrosion rate and remaining life in roll-off tanks using the Corrosion Monitoring method with the Non-Destructive Test (NDT) approach with visual inspection following the ASME VIII Div 1 standard, namely by making comparisons between roll-off tank design data and actual technical data regarding roll-off tank.…”
Section: 1mentioning
confidence: 99%
“…This vessel which located at LPG bulk filling station (SPBE) installation has a medium-high risk level with area of consequence 15430431.8 ft 2 . If a failure occurred this equipment will have an impact both on the plant and the surrounding environment [10]. The HRSG (Heat Recovery Steam Generator) in Muara Karang evaluated based on API 581 RBI method with inspected equipment including pressure vessel, heat exchangers, pipes and tubes.…”
Section: Introductionmentioning
confidence: 99%