2009
DOI: 10.1109/tns.2009.2024150
|View full text |Cite
|
Sign up to set email alerts
|

Studies of the Characteristics of a Silicon Neutron Sensor

Abstract: Abstract-Electrical

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
9
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 7 publications
0
9
0
Order By: Relevance
“…In addition, the geometry dependence has also been investigated and shows that the main parameter which influences the silicon detector's radiation response in terms of sensitivity and fluence measurement range is the thickness as it has been previously shown in [7]- [9] and [29].…”
Section: Discussionmentioning
confidence: 95%
See 2 more Smart Citations
“…In addition, the geometry dependence has also been investigated and shows that the main parameter which influences the silicon detector's radiation response in terms of sensitivity and fluence measurement range is the thickness as it has been previously shown in [7]- [9] and [29].…”
Section: Discussionmentioning
confidence: 95%
“…This is due to two factors: i) increasing of injection current density that is derived in details in [9] and ii) pure geometrical factor W/A (width over area of the detector) which is determined by increasing of resistance of the diode base due to increasing of resistivity of n-Si with irradiation.…”
Section: Influence Of the Active Areamentioning
confidence: 99%
See 1 more Smart Citation
“…It should be clearly pointed out that this approach was used because the mathematical formulation could conveniently and successfully be used to fit and parameterize the obtained experimental data. Other theoretical approaches towards the description of I-V curves, like for example used in [17]- [19] for diodes irradiated with neutrons up to 1 cm , follow the classical semiconductor theory and might thus be regarded as more fundamental and sound. However, aim of this work is not to compare these theoretical approaches, but to parameterize the obtained data.…”
mentioning
confidence: 99%
“…It shall be clearly stated that the results in this work are entirely based on the commercial BPW34FS diodes. Custom made diodes would obviously allow for further device modifications in terms of e.g., the diode base length and diode shape (see e.g., [17] and [19]), but remain to be developed, tested and optimized for the high fluences expected for the Super-LHC application.…”
mentioning
confidence: 99%