2015
DOI: 10.1007/s00170-015-6873-0
|View full text |Cite
|
Sign up to set email alerts
|

Studies on design of customized orthopedic endoprostheses of titanium alloy manufactured by SLM

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
15
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(17 citation statements)
references
References 13 publications
0
15
0
Order By: Relevance
“…This can be attributed to the reduced ratio of temperature gradient to solidification rate, as well as the increased turbulence of melt pools [75] . Increased laser intensity appears to increase density and therefore reduce porosity [76,77] . The increased laser intensity, while creating a larger immediate melt pool, also affects previous layers, resulting in increased heating/cooling cycles -this allows for microstructural refinement in much the same way as increased scan rates.…”
Section: Slm Part Propertiesmentioning
confidence: 99%
“…This can be attributed to the reduced ratio of temperature gradient to solidification rate, as well as the increased turbulence of melt pools [75] . Increased laser intensity appears to increase density and therefore reduce porosity [76,77] . The increased laser intensity, while creating a larger immediate melt pool, also affects previous layers, resulting in increased heating/cooling cycles -this allows for microstructural refinement in much the same way as increased scan rates.…”
Section: Slm Part Propertiesmentioning
confidence: 99%
“…The main advantages of 3D-printed custom implants are significant reduction in operative time, precise matching, quality assurance and improved biofunctionality. 21 With the implantation of prosthesis, the natural anatomy of the pelvis is to be restored by matching the prosthesis design to the patient's pelvis. Due to the complexity of pelvic bone and its fixation system, studies on the effectiveness of fixations and biomechanics of pelvic bone are rare.…”
Section: Introductionmentioning
confidence: 99%
“…The Young's modulus of a single crystalline beta-type Ti-15Mo-5Zr-3Al alloy has an anisotropic Young's modulus; the lowest Young's modulus is very close to that of bone along the specific crystallographic direction [34]. In addition, SLM can provide implants adapted to the bone shape of each patient [35], as in the present.…”
Section: Plos Onementioning
confidence: 51%