“…Conversely, the F group included various mass flow rates (110, 330, 440, 550, and 1100 g/min) of fine granules (ṁ F ) and a fixed mass flow rate of coarse granules (for F1, F2, F3, F4, and F5, respectively). A mass flow rate of 330 g/min was concluded to be the optima setup, as determined in our previous study [21]. These coarse and fine granules were controlled by two variable-frequency conveyers located under the MGBF.…”