2009
DOI: 10.1016/j.sab.2009.07.007
|View full text |Cite
|
Sign up to set email alerts
|

Study of matrix effects in laser induced breakdown spectroscopy on metallic samples using plasma characterization by emission spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
29
0
3

Year Published

2010
2010
2021
2021

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 61 publications
(33 citation statements)
references
References 17 publications
1
29
0
3
Order By: Relevance
“…plasma temperature and electron number density). It was suggested by Aguilera et al [129] that the volume of the plasma region observed and the total number of atoms in this volume also have to be considered when characterizing matrix effects or optimizing for their minimization. It is also worth pointing out that signal normalization using these same reference signals is also used with the purpose of improving the repeatability of LIBS signals, as was discussed in an earlier section.…”
Section: Quantitative Analysismentioning
confidence: 99%
“…plasma temperature and electron number density). It was suggested by Aguilera et al [129] that the volume of the plasma region observed and the total number of atoms in this volume also have to be considered when characterizing matrix effects or optimizing for their minimization. It is also worth pointing out that signal normalization using these same reference signals is also used with the purpose of improving the repeatability of LIBS signals, as was discussed in an earlier section.…”
Section: Quantitative Analysismentioning
confidence: 99%
“…Esto se debe al ensanchamiento de las líneas debida a la recombinación del H y el C en el propio plasma, así como a la disminución en la intensidad de dichas líneas cuando el plasma es producido a presión atmosférica (Aguilera et al 2009) (Aragón and Aguilera 2008).…”
Section: Resultsunclassified
“…This is an observed dependence of the intensity of the LIBS emission response to the nature of the material analysed (Eppler et al, 1996), which manifests as variations in laser-target coupling and resultant plasma intensity variations. These two facets of the sample, which are generally lumped together as "matrix effects" (Aguilera et al, 2009;Corsi et al, 2000;Ctvrtnickova et al;Lu et al, 2010;Ma et al;Mohamed, 2008;Shen et al, 2009;Windom & Hahn, 2009), will determine LIBS signal reproducibility, namely sample composition and sample surface character.…”
Section: Resultsmentioning