2019
DOI: 10.1109/access.2019.2930829
|View full text |Cite
|
Sign up to set email alerts
|

Study on Characteristic Parameters of Short-Circuit Impedance for a Four-Winding Inductive Filtering Transformer in Power System Supplying Nonlinear Loads

Abstract: Different from a three-winding transformer and ac passive filtering method, this paper proposes an inductive filtering (IF) method with a four-winding inductive filtering transformer (FW-IFT) for power system supplying nonlinear loads. Based on this, the characteristic parameters of the short-circuit impedance for the FW-IFT are studied in detail by theoretical analysis and experimental verification. According to the single-phase equivalent circuit, the voltage equations of the FW-IFT are established at the fu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 21 publications
0
3
0
Order By: Relevance
“…The induction filter technology proposed in [11]- [15] is different from the traditional harmonic control scheme. It is based on the magnetic potential balance between the transformer windings.…”
Section: Introductionmentioning
confidence: 99%
“…The induction filter technology proposed in [11]- [15] is different from the traditional harmonic control scheme. It is based on the magnetic potential balance between the transformer windings.…”
Section: Introductionmentioning
confidence: 99%
“…Domestic and foreign scholars have done a lot of research on the detection of transformer winding deformation and formed the following several mature detection methods. The short-circuit impedance method [5][6][7] has been promulgated by the International Electrotechnical Commission (IEC) standards and national standards. By comparing the short-circuit impedance values before and after the transformer winding deformation, it can be judged whether the winding has been deformed or shifted, but the sensitivity to the small deformation of the winding is not high.…”
Section: Introductionmentioning
confidence: 99%
“…Frequency response and low voltage pulse method have been widely used in the power industry, they are mainly be tested after the transformer quit operation in actual application [19][20]. Although short circuit reactance method can be used to monitor the winding deformation online [21], it cannot diagnose the early latent fault of winding loosened state. Recently, state monitoring method based on vibration information is becoming one of the research directions in transformer winding monitoring field [22][23][24].…”
Section: Introductionmentioning
confidence: 99%