2012
DOI: 10.4028/www.scientific.net/amr.535-537.1126
|View full text |Cite
|
Sign up to set email alerts
|

Study on Multi-Elements in Traditional Chinese Medicines <i>Ophiopogon japonicus</i> and Lotus Seeds by the ICP-AES with Microwave Digestion

Abstract: Abstract: Determination of multi-elements were studied in the food cooked with medicinal herbs Ophiopogon japonicus(OJ) and Lotus seeds by ICP-AES after HNO3-H2O2 digestion with microwave. The average recoveries are in 91.7%~ 102.4% of As, Cr, Se, Cd, Cu, Mn, Zn, Al, Ba, Fe, Ni, respectively. The relative standard deviation(RSD)is less than 2.8% except Al (9.4%)and detection limit is in the range of 0. 10µg/L ~8.5µg/L except Al (79.6µg/L). The difference was very obvious(p0.001,except As) that the ele… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
1
0

Year Published

2012
2012
2018
2018

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 27 publications
0
1
0
Order By: Relevance
“…The sample (0.3 g of dry black or brown seeds for each sample) was prepared by microwave digestion in HNO 3 -H 2 O 2 , and ultrapure water was added to obtain a final volume of 25 mL [ 74 ]. Then, these were analyzed using an inductively coupled plasma (ICP-OES) spectrometer (Optima 7300 DV, Perkin-Elmer, USA).…”
Section: Methodsmentioning
confidence: 99%
“…The sample (0.3 g of dry black or brown seeds for each sample) was prepared by microwave digestion in HNO 3 -H 2 O 2 , and ultrapure water was added to obtain a final volume of 25 mL [ 74 ]. Then, these were analyzed using an inductively coupled plasma (ICP-OES) spectrometer (Optima 7300 DV, Perkin-Elmer, USA).…”
Section: Methodsmentioning
confidence: 99%
“…Inductively coupled plasma atomic emission spectrometry (ICP-AES) is a rapid and accurate technique for the simultaneous determination of the minor and major element contents [6][7][8]. In the digestion step the organic matter present in the seeds is destroyed in order to reduce interferences during the ICP-AES measurements.…”
Section: Introductionmentioning
confidence: 99%
“…and the heavy metals deposition can cause damaging effect on human system [1]. Most of the standard methods for determination of atmospheric heavy metals include ICP-MS [2][3][4][5], AAS [6][7], ICP-AES [8], etc. These methods often adopt an aerosol sampler with filters to collect particles in the air, and then the filters are used for lab analysis.…”
Section: Introductionmentioning
confidence: 99%