2009
DOI: 10.1016/j.saa.2009.02.010
|View full text |Cite
|
Sign up to set email alerts
|

Study on solid phase extraction and spectrophotometric determination of vanadium with 2,3-dichloro-6-(2,7-dihydroxy-1-naphthylazo)quinoxaline

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
16
0

Year Published

2009
2009
2016
2016

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(16 citation statements)
references
References 37 publications
0
16
0
Order By: Relevance
“…Conventional solid phase extraction techniques, require sophisticated, expensive, nonportable equipment, thus limiting their usefulness as real-time detection systems [28][29][30][31][32][33][34][35][36]. SPE is a laboratory method and cannot be transported to the field for onsite measurements.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Conventional solid phase extraction techniques, require sophisticated, expensive, nonportable equipment, thus limiting their usefulness as real-time detection systems [28][29][30][31][32][33][34][35][36]. SPE is a laboratory method and cannot be transported to the field for onsite measurements.…”
Section: Discussionmentioning
confidence: 99%
“…SPE is a laboratory method and cannot be transported to the field for onsite measurements. The solid phase extraction reduces solvent requirements, but it does not eliminate them completely [28,31,33,36]. A comparison of the proposed system with some recent studied procedures is given in Table 4.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Based on Refs. [17][18][19][20], the authors proposed and explored the two types of techniques, namely the SPE and the LLE of the quaternary ammonium surfactant. The joint research of the two types of techniques obtained satisfactory results, and we are looking forward to discovering some new highlights and enriching the knowledge of extraction chemistry in theory.…”
Section: Introductionmentioning
confidence: 99%
“…This would greatly expand its applications, especially for the less developed area without more advanced analytical instruments. But recently, few works were carried out in this field, except for solvent extraction [16,17], solid phase extraction [18,19], cloud point extraction and surfactant-mediated extraction [20][21][22] In our previous work, dispersive liquid liquid microextraction (DLLME) [23] and single drop microextraction (SDME) [10] were investigated to be combined with ordinary spectrophotometer. In this work, UV-vis spectrophotometry was applied to hyphenate with ionic liquid-based SDME for the determination of copper in water and food samples.…”
Section: Introductionmentioning
confidence: 99%