2013
DOI: 10.1016/j.talanta.2013.03.026
|View full text |Cite
|
Sign up to set email alerts
|

Study on stability mechanism of immobilized pH gradient in isoelectric focusing via the Svensson–Tiselius differential equation and moving reaction boundary

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 31 publications
0
7
0
Order By: Relevance
“…In Panel B, the RSD values of p I 6.8, 7.04, 7.09, and 7.13 for the samples of Group 2 were respectively 4.79, 5.19, 3.66, and 2.10%, and in Panel C the ones of p I 6.8, 7.04, 7.09, and 7.13 for the samples of Group 3 were 6.27, 3.92, 2.17, and 2.77%, respectively. All the data suggested fair stability and reliability of the protocol due to the IPG technique and equivalent fluxes of hydrogen and hydroxyl ions .…”
Section: Resultsmentioning
confidence: 83%
See 2 more Smart Citations
“…In Panel B, the RSD values of p I 6.8, 7.04, 7.09, and 7.13 for the samples of Group 2 were respectively 4.79, 5.19, 3.66, and 2.10%, and in Panel C the ones of p I 6.8, 7.04, 7.09, and 7.13 for the samples of Group 3 were 6.27, 3.92, 2.17, and 2.77%, respectively. All the data suggested fair stability and reliability of the protocol due to the IPG technique and equivalent fluxes of hydrogen and hydroxyl ions .…”
Section: Resultsmentioning
confidence: 83%
“…However, if the grind time was more than 30 min, long focusing time and high current were observed in the IEF run, resulting in a poor electrofocusing (). This was due to the factor that more salt was released into the extracting sample from the meat tissue if long‐term extraction was given, leading to poor IEF results .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…It must be also noted that the mathematical model for stream broadening described in this manuscript is only applicable to systems with a stable pH gradient. In assays where this gradient fluctuates temporally due to uncontrollable factors [41,42] or is intentionally varied with time [43,44], the noted analysis may not be valid. In addition, it has been recently suggested that the production of water in isoelectric focusing system can also lead to zone broadening which again has not been accounted for in the current study [41,45].…”
Section: Resultsmentioning
confidence: 99%
“…Moreover, the solubilizing agents must be compatible with isoelectric focusing (IEF) and preserve the protein solubilization at critical steps, e.g., at the sample entry into the gel and/or when protein achieves its isoelectric point [29]. Nevertheless, other strategies should be considered to avoid gel-to-gel variation, including the refinement and tuning of protein separation by isoelectric point (pI) [30][31][32][33][34] and by molecular weight (MW) [33,35,36].…”
Section: Introductionmentioning
confidence: 99%