SU‐E‐T‐96: Energy Dependence of the New GafChromic‐ EBT3 Film's Dose Response‐Curve

Abstract: The dose response curves for GafChromic EBT3 films were found to be weakly dependent on the energy of the photon beams from 6MV to 50kV. The degree of energy dependence varies with color channel, dose and spatial resolution. GafChromic EBT3 films were supplied by Ashland Corp. This work was partially supported by DGAPA-UNAM grant IN102610 and Conacyt Mexico grant 127409.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
21
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 22 publications
(23 citation statements)
references
References 0 publications
1
21
1
Order By: Relevance
“…Other advantages of choosing smaller resolution might include smaller image file size and quicker scanning time due to lesser working memory requirement. However, Chiu-Tsao et al [25] argued that a sharper resolution of 300 dpi would be crucial for brachytherapy and other small field applications (stereotactic radiosurgery, stereotactic body radiation therapy) as an accurate dose distribution measurement are highly demanded.…”
Section: Discussionmentioning
confidence: 99%
“…Other advantages of choosing smaller resolution might include smaller image file size and quicker scanning time due to lesser working memory requirement. However, Chiu-Tsao et al [25] argued that a sharper resolution of 300 dpi would be crucial for brachytherapy and other small field applications (stereotactic radiosurgery, stereotactic body radiation therapy) as an accurate dose distribution measurement are highly demanded.…”
Section: Discussionmentioning
confidence: 99%
“…Far too many publications fail to provide sufficient detail to enable replication of radiation delivery, and even fewer provide details regarding the frequency and type of calibration performed [57]. At our institution, monthly quality assurance (QA) is performed by a member of the UW Calibration Lab using a custom-built compact 4 × 4 cm phantom and Gafchromic EBT3 film which has known spatial precision and relatively flat energy response [58]. At a minimum, we suggest that monthly QA be performed to ensure the dose The transition from cesium irradiators, with their easily calculated dose rate, has highlighted the importance of dosimetric validation for pre-clinical irradiation.…”
Section: Radiation Deliverymentioning
confidence: 99%
“…Far too many publications fail to provide sufficient detail to enable replication of radiation delivery and even fewer provide details regarding the frequency and type of calibration performed [50]. At our institution, monthly quality assurance is performed by a member of the UW Calibration Lab using a custom-built compact 4x4cm phantom and Gafchromic EBT3 film which has known spatial precision and relatively flat energy response [51]. At a minimum, we suggest that monthly QA be performed to ensure the dose rate is correct and, for small animal image guided systems, to confirm alignment of the beam with the isocenter.…”
Section: Radiation Deliverymentioning
confidence: 99%