2013
DOI: 10.3357/asem.3550.2013
|View full text |Cite
|
Sign up to set email alerts
|

Subjective and Objective Measures of Relaxed +G<SUB>z</SUB> Tolerance Following Repeated +G<SUB>z</SUB> Exposure

Abstract: Frequent +Gz acceleration, either as 2 (8 SACMs) or 4 sessions (16 SACMs) per week for 3 wk, enhances cardiovascular tolerance to orthostatic stress but does not improve RGT measured during a GOR.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 14 publications
(8 citation statements)
references
References 11 publications
0
8
0
Order By: Relevance
“…In this study, the average values of RGT and SGT were 5.1 G and 7.8 G, respectively, among the participants. Previous results have noted that age, flight experience/hour [24,25], and repeated exposure to a high-G environment [2,9,26] were positive factors correlated with G tolerance. The mild discrepancy in SGT might well result from the different age subgroups of male military aircrew members.…”
Section: Discussionmentioning
confidence: 97%
“…In this study, the average values of RGT and SGT were 5.1 G and 7.8 G, respectively, among the participants. Previous results have noted that age, flight experience/hour [24,25], and repeated exposure to a high-G environment [2,9,26] were positive factors correlated with G tolerance. The mild discrepancy in SGT might well result from the different age subgroups of male military aircrew members.…”
Section: Discussionmentioning
confidence: 97%
“…Repeated exposure to LAHC can improve orthostatic tolerance (Scott et al . 2013), but is impractical and thus unlikely to be employed during spaceflight (Clément & Pavy‐Le Traon, 2004).…”
Section: Introductionmentioning
confidence: 99%
“…almost constant gravitational force is experienced at the head and feet, Scott et al 2007). Repeated exposure to LAHC can improve orthostatic tolerance (Scott et al 2013), but is impractical and thus unlikely to be employed during spaceflight (Clément & Pavy-Le Traon, 2004).…”
Section: Introductionmentioning
confidence: 99%
“…Heart rate (HR) was determined continuously from a three-lead ECG. Beat-to-beat blood pressure (Finapres 2300, Ohmeda, USA) was recorded using the volume-clamp method 25 , which is well-established for non-invasive trend monitoring in centrifuge studies 7,29 and has been shown to correlate well with intra-arterial line measurements 21 . .…”
Section: Anti-g Systems: Three Anti-g Systems Were Evaluated System 1 [S1] and Systemmentioning
confidence: 99%
“…All AGT elevate arterial blood pressure by increasing total peripheral resistance (TPR) and promoting venous return, which assists in the maintenance of stroke volume (SV) and thereby cardiac output (CO) 13 . Despite these effects, the assessment of G protection effectiveness has largely been confined to subjective estimates of the G-level reached at pre-determined visual end-points 16,24,29 .…”
Section: Introductionmentioning
confidence: 99%