2008
DOI: 10.3928/01477447-20080601-09
|View full text |Cite
|
Sign up to set email alerts
|

Subtrochanteric Fracture in a Patient With Trabecular Metal Osteonecrosis Intervention Implant

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2010
2010
2019
2019

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 9 publications
0
5
0
Order By: Relevance
“…Comparing the complications after insertion of the TI with previous literature, Nadeau et al determined one subtrochanteric fracture four weeks postoperatively within a group of 18 ONFH [15]. A similar case of a subtrochanteric fracture after insertion of the TI was described by Fung et al [9]. Two other studies analysing the treatment of TI revealed no fracture [17,21].…”
Section: Load Bearingmentioning
confidence: 83%
“…Comparing the complications after insertion of the TI with previous literature, Nadeau et al determined one subtrochanteric fracture four weeks postoperatively within a group of 18 ONFH [15]. A similar case of a subtrochanteric fracture after insertion of the TI was described by Fung et al [9]. Two other studies analysing the treatment of TI revealed no fracture [17,21].…”
Section: Load Bearingmentioning
confidence: 83%
“…Metal trabecular material positively affected bone ingrowth for stability of secondary implant (Spinato et al, 2014). As a fairly novel and special material, metal trabecular is reported to resemble bone more than any other prosthesis physically and mechanically, and no major complications were uncovered after treatment (Fung, Frey, Menkowitz, & Mark, 2008). Studies focusing on ONFH suggested that metal trabecular rods implantation, and metal-onmetal total hip resurfacing arthroplasty can serve as advisable options for treating ONFH and severe femoral bone defects (Mont, Seyler, Marker, Marulanda, & Delanois, 2006;Tischler, Hansen, & Austin, 2014).…”
Section: Discussionmentioning
confidence: 99%
“…36,37 Concerns over weakening the femoral neck by drilling of the lateral cortex for insertion of a 10 mm tantalum rod are well founded with reports of five patients having sustained a subtrochanteric fracture post-operatively after a fall. 13,17,18,38 Since the length and diameter of the pegs are small and they do not engage the lateral cortex, and the two or three drillholes of 4 mm (or 4.5 mm) are dispersed, less stress might be generated at the lateral cortex compared with a single hole of more than 10 mm. Moreover, the small length of the pegs eliminates the need to cut the metal and disperse metallic debris, in case of a possible future conversion to a THR.…”
Section: Discussionmentioning
confidence: 99%