2017
DOI: 10.3390/s17122954
|View full text |Cite
|
Sign up to set email alerts
|

Sulfophenyl-Functionalized Reduced Graphene Oxide Networks on Electrospun 3D Scaffold for Ultrasensitive NO2 Gas Sensor

Abstract: Ultrasensitive room temperature real-time NO2 sensors are highly desirable due to potential threats on environmental security and personal respiratory. Traditional NO2 gas sensors with highly operated temperatures (200–600 °C) and limited reversibility are mainly constructed from semiconducting oxide-deposited ceramic tubes or inter-finger probes. Herein, we report the functionalized graphene network film sensors assembled on an electrospun three-dimensional (3D) nanonetwork skeleton for ultrasensitive NO2 sen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 21 publications
(6 citation statements)
references
References 33 publications
0
6
0
Order By: Relevance
“…Donor groups like amidogen (-NH 2 ) on organic molecules enhance electron transfer between gas molecules and graphene. 159,160 Wan et al created a flexible, transparent graphene-polyaniline (PANI) nanocomposite film for highly sensitive NH 3 detection. The wearable sensor detected NH 3 from 100 ppb to 100 ppm with a rapid response and recovery times of 36s and 18s, respectively.…”
Section: Carbonaceous Materialsmentioning
confidence: 99%
“…Donor groups like amidogen (-NH 2 ) on organic molecules enhance electron transfer between gas molecules and graphene. 159,160 Wan et al created a flexible, transparent graphene-polyaniline (PANI) nanocomposite film for highly sensitive NH 3 detection. The wearable sensor detected NH 3 from 100 ppb to 100 ppm with a rapid response and recovery times of 36s and 18s, respectively.…”
Section: Carbonaceous Materialsmentioning
confidence: 99%
“…Michael E. Smith [236] devel- ops a novel wearable vision H 2 sensor for non-invasive monitoring of biodegradation of magnesium implants in vivo in medical research and clinical Settings. The development of a real-time NO 2 sensor is also of interest [237]. Hua et al [238].…”
Section: Environmental Monitoringmentioning
confidence: 99%
“…The following section explains the gas sensing capability of rGO-loaded metal oxide NFs. This paper does not discuss the combination of rGO with other materials, such as mesh fabric [ 53 ] or polymers [ 54 , 55 ], for gas sensing studies. Furthermore, composites of metal oxides-rGO in morphologies other than NFs are not discussed.…”
Section: Graphene Graphene Oxide and Reduced Graphene Oxidementioning
confidence: 99%