2019
DOI: 10.1002/jlcr.3701
|View full text |Cite
|
Sign up to set email alerts
|

[18F]FPyZIDE: A versatile prosthetic reagent for the fluorine‐18 radiolabeling of biologics via copper‐catalyzed or strain‐promoted alkyne‐azide cycloadditions

Abstract: Methods for the radiolabeling of biologics with fluorine-18 have been of interest for several decades. A common approach consists in the preparation of a prosthetic reagent, a small molecule bearing a fluorine-18 that is conjugated with the macromolecule to an appropriate function. Click chemistry, and more particularly cycloadditions, is an interesting approach to radiolabel molecules thanks to mild reaction conditions, high yields, low by-products formation, and strong orthogonality. Moreover, the chemical f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
15
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(15 citation statements)
references
References 55 publications
0
15
0
Order By: Relevance
“…To improve the efficiency of 18 F radiolabeling, Roche et al explored a new 18 F-labeled azide prosthetic group, 18 F-FPyZIDE (Table 1, entry 6). In their study, the radiolabeled tracers were evaluated in both CuAAC- and SPAAC-based ligations and the labeling results showed that both radiolabeling methods provided high RCYs under mild reaction conditions (room temperature or 40 °C) [60]. Evans et al investigated the radiosynthesis of 68 Ga-labeled peptide using azide group-bearing 1,4,7,10-tetraazacyclododecane-tetraacetic acid (DOTA) chelator and DBCO group conjugated cRGD peptide (Table 1, entry 7) [61].…”
Section: Strained Promoted Copper-free Click Reaction For Synthesimentioning
confidence: 99%
“…To improve the efficiency of 18 F radiolabeling, Roche et al explored a new 18 F-labeled azide prosthetic group, 18 F-FPyZIDE (Table 1, entry 6). In their study, the radiolabeled tracers were evaluated in both CuAAC- and SPAAC-based ligations and the labeling results showed that both radiolabeling methods provided high RCYs under mild reaction conditions (room temperature or 40 °C) [60]. Evans et al investigated the radiosynthesis of 68 Ga-labeled peptide using azide group-bearing 1,4,7,10-tetraazacyclododecane-tetraacetic acid (DOTA) chelator and DBCO group conjugated cRGD peptide (Table 1, entry 7) [61].…”
Section: Strained Promoted Copper-free Click Reaction For Synthesimentioning
confidence: 99%
“…103 This work suggested that this tracer could be potentially employed to noninvasively quantify PD-1/PD-L1 expression in clinical studies. Zeng et al described the production and evaluation of 64 Cu-labeled ubiquitin protein ([ 64 Cu]CB-1K1P-UbCG4), synthesized using the TCO-Tz ligation of IEDDA, for a chemokine receptor (CXCR4) imaging (Figure 4C). 104 In this study, the results demonstrated that 64 Cu-labeled ubiquitin displayed selective and specific binding affinities with CXCR4 receptors, and PET imaging results in mice bearing 4T1-xenograft tumors revealed clear visualization of the xenografted tumor at 1 and 2 h as well as comparable tumor uptake values between [ 64 Cu]CB-1K1P-UbCG4 and [ 64 Cu]AMD3465.…”
mentioning
confidence: 99%
“…The 64 Cu-labeled cetuximab radiotracers conjugated with two cross-bridged macrocyclic chelators (CBTE1A1P and CBTE1K1P) were constructed based on SPAAC reaction. 105 Compared with other 64 Cu-labeled cetuximab radio-conjugates, the results of these two radiotracers in PET imaging experiment showed a more rapid renal elimination and a more remarkable tumor-tobackground ratio. Using the same radiometal, Lee et al reported the radiolabeling of trastuzumab using a CuAAC reaction, in which the propylene cross-bridged chelator (PCB-TE2A-alkyne) reacted with a Tz-containing azide.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…The azide–alkyne Huisgen reaction has become a widely used cross-coupling strategy in various fields including radiolabeling. While typical click reactions require transition metal catalysts, SPAAC is catalyst free and biorthogonal and has no residual metal toxicity concerns. , 18 F PET agent constructions utilizing SPAAC alkynes have been reported by various groups (Figure b). Even though the reported examples are successful, the implications of these methods in new PET agent development remain limited. This could be caused by the lack of modular design and incompatibility between substrate stability and reaction rate.…”
mentioning
confidence: 99%