2013 IEEE International Conference on Industrial Technology (ICIT) 2013
DOI: 10.1109/icit.2013.6505945
|View full text |Cite
|
Sign up to set email alerts
|

Support of grid voltages with asymmetrical reactive currents in case of grid errors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(6 citation statements)
references
References 3 publications
0
6
0
Order By: Relevance
“…3 (see point B). This minimum injection of reactive current results in lower V max , as predicted by (23)- (25). On the contrary, the reactive current takes the maximum value in the lowest power production scenario (see Fig.…”
Section: Voltage Support Propertiesmentioning
confidence: 58%
See 2 more Smart Citations
“…3 (see point B). This minimum injection of reactive current results in lower V max , as predicted by (23)- (25). On the contrary, the reactive current takes the maximum value in the lowest power production scenario (see Fig.…”
Section: Voltage Support Propertiesmentioning
confidence: 58%
“…It has been shown by the experimental validation that the proposed control incorporates all the desired characteristics specified by the control objectives. [3,4] no no yes no no not specified [18,24] no yes yes no no not specified [25] yes no yes no no not specified [9] yes yes yes no no any value [26] no yes yes yes no any value [33] no yes yes no no any value [36] no no yes no yes X /R ≪ 1 [5]…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In case of a symmetrical fault, which is a voltage dip in all three phases, the requested reactive current can rise up to 100 % of the nominal current of the wind turbine. By By feeding symmetrical reactive currents in case of an asymmetrical grid fault special attention has to be paid to the voltages in the undistorted phases [6]. In a similar manner the reactive power supports the grid voltage in the distorted phase, the voltage in the undistorted phase will increase reasoned by the feed-in of the reactive current.…”
Section: Grid Code Requirementsmentioning
confidence: 99%
“…The grid fault is detected by analyzing the individual phase voltages. Furthermore, to prevent an increase of the voltage in the undistorted phase in case of an asymmetrical grid fault, asymmetrical reactive current has to be fed into the grid [6].…”
Section: Grid Code Requirementsmentioning
confidence: 99%