1994
DOI: 10.1002/bbpc.19940980356
|View full text |Cite
|
Sign up to set email alerts
|

Surface‐ and interfacial tensions of liquid crystalline polymers

Abstract: Surface tensions (γA) of two side group liquid‐crystalline (lc) polymethacrylates and the interfacial tensions (γAB) between the lc‐polymers (LCP) and branched polyethylen respectively polymethylmethacrylat were measured in the isotropic and nematic phase with the pendant‐drop method. The surface tensions vs. temperature characteristics show anomalous behavior. The slope is initially negative but changes its sign near the isotropic‐nematic transition. This behavior is in agreement with surface‐tension measurem… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

1998
1998
2003
2003

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 7 publications
0
7
0
Order By: Relevance
“…In general, the equilibrium static methods are most commonly used. They involve the evaluation of a profile of either a sessile drop [3][4][5][6][7][8][9][10][11] , or a spinning drop [12][13][14][15][16] or a pendant drop [17][18][19][20][21][22][23][24][25][26][27] . Dynamic methods, based on the breaking thread and imbedded fiber were also used [28][29][30][31][32][33][34][35] to determine interfacial tension.…”
Section: Introductionmentioning
confidence: 99%
“…In general, the equilibrium static methods are most commonly used. They involve the evaluation of a profile of either a sessile drop [3][4][5][6][7][8][9][10][11] , or a spinning drop [12][13][14][15][16] or a pendant drop [17][18][19][20][21][22][23][24][25][26][27] . Dynamic methods, based on the breaking thread and imbedded fiber were also used [28][29][30][31][32][33][34][35] to determine interfacial tension.…”
Section: Introductionmentioning
confidence: 99%
“…The densities of the polymers were measured by an automated capillary mercury dilatometer. [1][2] The measurement setup reaches a sensitivity of l 0.001 g/cm 3 with approximately 200 mg of sample.…”
Section: Density Determinationsmentioning
confidence: 99%
“…In contrast to the most common polymers, only few reports have been published regarding the surface-energetic investigations on LCPs [1][2][3] until now. In our previous papers, [1][2][3] it was pointed out that such measurements are seriously limited by the generally high viscosity of LCPs, and for this reason the pendant drop method has been demonstrated to be the only suitable method.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations