2014
DOI: 10.1115/1.4026145
|View full text |Cite
|
Sign up to set email alerts
|

Surge Onset in Turbo Heat Pumps

Abstract: A typical turbo heat pump system consists of a centrifugal compressor, expansion valve, and two heat exchangers—a condenser and evaporator. Compared to a gas turbine, a turbo heat pump introduces additional complexities because it is a two-phase closed-loop system with heat exchange using a real gas/liquid (refrigerant) as the working fluid. For the first time, surge onset in such systems has been physically, analytically, and experimentally investigated. This study analytically investigates the physical mecha… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 10 publications
0
2
0
Order By: Relevance
“…Amongst these, turbo heat pumps which utilizes radial compressors are preferred, when possible, as they offer compact and silent operation as compared to positive displacement devices. Turbo heat pumps, which use dynamic compressors, move heat from a low temperature reservoir to a high temperature reservoir, by circulating the refrigerant through a centrifugal compressor, an expansion valve and two heat exchangers -a condenser and an evaporator [7]. The compressor in this system is susceptible to surge & stall instabilities just like any other radial compressors.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Amongst these, turbo heat pumps which utilizes radial compressors are preferred, when possible, as they offer compact and silent operation as compared to positive displacement devices. Turbo heat pumps, which use dynamic compressors, move heat from a low temperature reservoir to a high temperature reservoir, by circulating the refrigerant through a centrifugal compressor, an expansion valve and two heat exchangers -a condenser and an evaporator [7]. The compressor in this system is susceptible to surge & stall instabilities just like any other radial compressors.…”
Section: Introductionmentioning
confidence: 99%
“…Song et. al [7] and Kim and Song [11] later developed a model to better match the operation of a radial compressor in a closed loop refrigerant cycle. These developments demonstrate the need for a clear understanding of the operation & performance analysis of a dynamic compressor-driven heat pump.…”
Section: Introductionmentioning
confidence: 99%