2001
DOI: 10.1002/1521-3935(20010101)202:1<97::aid-macp97>3.0.co;2-c
|View full text |Cite
|
Sign up to set email alerts
|

Synthesis and Hemocompatibilities of Cellulose-Containing Segmented Polyurethanes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2006
2006
2015
2015

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(7 citation statements)
references
References 5 publications
0
7
0
Order By: Relevance
“…The characteristic absorption peaks of the PU are observed at 3300 cm À1 (N-H stretching frequency), 2927-2890 cm À1 (-CH 2 -stretching frequencies), 1734 cm À1 (carbonyl urethane stretching), 1540 cm À1 (CHN vibration), 1270 cm À1 (coupled C-N and C-O stretching), 825 cm À1 (aromatic C-H stretching) and 1079 cm À1 (C-O stretching). The characteristic peak for -NCO (2250-2275 cm À1 ) disappeared after polymerization, indicating polymerization reaction completion [19][20][21][22]. The absence of absorbance at 2267 cm À1 indicated that there were no unreacted isocyanate groups in the PU [18][19][20].…”
Section: Characterization Of Cla-based Pusmentioning
confidence: 99%
See 1 more Smart Citation
“…The characteristic absorption peaks of the PU are observed at 3300 cm À1 (N-H stretching frequency), 2927-2890 cm À1 (-CH 2 -stretching frequencies), 1734 cm À1 (carbonyl urethane stretching), 1540 cm À1 (CHN vibration), 1270 cm À1 (coupled C-N and C-O stretching), 825 cm À1 (aromatic C-H stretching) and 1079 cm À1 (C-O stretching). The characteristic peak for -NCO (2250-2275 cm À1 ) disappeared after polymerization, indicating polymerization reaction completion [19][20][21][22]. The absence of absorbance at 2267 cm À1 indicated that there were no unreacted isocyanate groups in the PU [18][19][20].…”
Section: Characterization Of Cla-based Pusmentioning
confidence: 99%
“…This phenomenon may be attributed to crosslinking of the quinic acid block came from CLA in the polymer structure. As a result, all the polyurethanes suitable for usage in medical application because of exhibit high thermal stability (Td > 280 C) [22][23][24][25][26].…”
Section: Characterization Of Cla-based Pusmentioning
confidence: 99%
“…The development of macromolecular syntheses from renewable carbon resources and the circulation system of the macromolecules are essential for human life 1. Thus acidic saccharide derivatives such as aldaric, aldonic, and alduronic acids have also been in use as starting blocks, for biomedical and/or biodegradable polymeric materials 2–24…”
Section: Introductionmentioning
confidence: 99%
“…The number of adhered platelet is sensitive also to the soft segment length in the case of fluorinated polyurethanes, (Wang & Wei, 2005). The presence of cellulose in segmented polyurethane matrix indeed inhibits platelet adhesion, (Hanada et al, 2001). For PU/hydrophilic poly(ethylene glycol)diacrylate IPNs, platelet adhesion is suppressed by microseparated IPN structure, (Yoon et al, 2005).…”
Section: Platelet Adhesionmentioning
confidence: 99%