2022
DOI: 10.3390/chemosensors10110459
|View full text |Cite
|
Sign up to set email alerts
|

Synthesis of Molecularly Imprinted Polymer Nanoparticles for SARS-CoV-2 Virus Detection Using Surface Plasmon Resonance

Abstract: COVID-19 caused by a SARS-CoV-2 infection was first reported from Wuhan, China, and later recognized as a pandemic on March 11, 2020, by the World Health Organization (WHO). Gold standard nucleic acid and molecular-based testing have largely satisfied the requirements of early diagnosis and management of this infectious disease; however, these techniques are expensive and not readily available for point-of-care (POC) applications. The COVID-19 pandemic of the 21st century has emphasized that medicine is in dir… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
11
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
3

Relationship

2
6

Authors

Journals

citations
Cited by 21 publications
(11 citation statements)
references
References 52 publications
0
11
0
Order By: Relevance
“…Classification of positive and negative swab samples was 95% sensitive and 100% specific (Figure c), including detection of negative oropharyngeal swab samples (from 21 different uninfected volunteers) and positive oropharyngeal swab samples (ranging from 250 to 10,000 TU μL –1 ). The 100% specificity and sensitivity achieved with portable Raman spectrometers (Table S3 and Figure S8) are critical for moving this technique from the laboratory to the field. , …”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Classification of positive and negative swab samples was 95% sensitive and 100% specific (Figure c), including detection of negative oropharyngeal swab samples (from 21 different uninfected volunteers) and positive oropharyngeal swab samples (ranging from 250 to 10,000 TU μL –1 ). The 100% specificity and sensitivity achieved with portable Raman spectrometers (Table S3 and Figure S8) are critical for moving this technique from the laboratory to the field. , …”
Section: Resultsmentioning
confidence: 99%
“…The 100% specificity and sensitivity achieved with portable Raman spectrometers ( Table S3 and Figure S8 ) are critical for moving this technique from the laboratory to the field. 37 , 38 …”
Section: Resultsmentioning
confidence: 99%
“…Further, binding kinetics studies were conducted using an excel solver (1) and Origin Pro 8.5. The details of which can be found elsewhere [50].…”
Section: Bsa Binding Assay-immunosensingmentioning
confidence: 99%
“…For this, adsorption isotherms (Langmuir, Freundlich, and Langmuir-Freundlich) were used and fitted to the relative response of experimental data, as shown in Figure 8d. Langmuir and Langmuir-Freundlich isotherms were fitted using an excel solver from Umpleby et al [52], whereas the Freundlich isotherm was fitted using the alometric1 (classical Freundlich) function from Origin pro 8.5 [50]. All the fitting parameters were calculated from the method mentioned in the above reference to compare and find out the best-fitted model (Table 1).…”
Section: Bsa-binding Assay and Kineticsmentioning
confidence: 99%
“…These fully synthetic receptors can bind to a specific target with high affinity due to the complementary cavities in the polymer matrix matching the analyte in terms of shape, size, and chemical functionality . A wide range of analytes have been targeted with MIP-based receptors including small molecules like glucose, pharmaceuticals, and endotoxins to large entities such as proteins, viruses, and bacteria . However, imprinting large biosystems is problematic due to the complex and unstable conformational structure leading to the formation of less efficient binding sites .…”
mentioning
confidence: 99%