IEEE/PES Transmission and Distribution Conference and Exhibition
DOI: 10.1109/tdc.2002.1177603
|View full text |Cite
|
Sign up to set email alerts
|

System study of direct current power transmission system connected to wind farm

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 2 publications
0
4
0
Order By: Relevance
“…Previously, the authors applied the conventional control used for DC transmission (that is, the aforementioned receiving-side control) on both sides, and examined feedback frequency control in the initial stage of active power control on the sending side [4]. However, it required switching of the frequency control on the sending side in the transition from start-up to power generation.…”
Section: Control On Receiving Sidementioning
confidence: 99%
See 1 more Smart Citation
“…Previously, the authors applied the conventional control used for DC transmission (that is, the aforementioned receiving-side control) on both sides, and examined feedback frequency control in the initial stage of active power control on the sending side [4]. However, it required switching of the frequency control on the sending side in the transition from start-up to power generation.…”
Section: Control On Receiving Sidementioning
confidence: 99%
“…In addition, some proposals have been made regarding power transmission from windfarms [2,3], and such systems are being investigated at the experimental level. As regards self-commutated HVDC transmission from windfarms, the authors studied the case in which there are no AC sources other than wind power generators on the windfarm side [4,5]; no other detailed reports are available.…”
Section: Introductionmentioning
confidence: 99%
“…In [6], it has been suggested that VSC are preferred for multi terminal DC (MTDC) because power flow can be reversed without changing the polarity of dc link voltage. In weak power system short circuit can be prevented by blocking of signals of wind farm converters [7]. In [8], fault study has been done using empirical mode decomposition which requires phasor measurement unit (PMU) or communication network which is very expensive.…”
Section: Introductionmentioning
confidence: 99%
“…We have proposed basic control for such a system that enabled stable power transmission of all generated power. (Noro, 2002, Tanomura, 2006 The generated power fluctuates depending on changes in wind velocity; therefore, power levelling is desirable for the receiving power system to relax stress on the generator governors. This paper proposes power levelling controls that are demonstrated by digital simulation using the ATPDraw5 program (Hoidalen, 2007).…”
Section: Introductionmentioning
confidence: 99%