2015
DOI: 10.1016/j.jhazmat.2014.08.027
|View full text |Cite
|
Sign up to set email alerts
|

Systematic optimization of an SPE with HPLC-FLD method for fluoroquinolone detection in wastewater

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
25
0
1

Year Published

2015
2015
2022
2022

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 84 publications
(26 citation statements)
references
References 57 publications
0
25
0
1
Order By: Relevance
“…The method has been reported elsewhere [17]; the literature has shown SPE with HPLC-FLD to be an effective means of measuring FQ antibiotics in environmental media [17][18][19][20]. Briefly, FQs were extracted from wastewater and environmental samples using weak cation exchange SPE cartridges (Oasis WCX 150 mg, 6 cc).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The method has been reported elsewhere [17]; the literature has shown SPE with HPLC-FLD to be an effective means of measuring FQ antibiotics in environmental media [17][18][19][20]. Briefly, FQs were extracted from wastewater and environmental samples using weak cation exchange SPE cartridges (Oasis WCX 150 mg, 6 cc).…”
Section: Methodsmentioning
confidence: 99%
“…The FQs were quantified by fluorescence detection, which was optimized for individual antibiotics [17]. Coefficients of determination for calibration curves were generally greater than 0.999.…”
Section: Methodsmentioning
confidence: 99%
“…posteriormente, se acondicionó la muestra para lograr un pH y fuerza iónica similar a la de la solución reguladora de pH = 3,81 y se realizaron 4 diluciones seriadas en la misma, a partir de la muestra original, considerada como dilución 1 o sin diluir (M1): dilución 0,8 o 1/1,25 (M2); dilución 0,5 o 1/2 (M3); dilución 0,25 o 1/4 (M4); dilución 0,1 o 1/10 (M5). A cada una de estas soluciones (M1-5), se le estimó la turbidez mediante la determinación espectrofotométrica de la absorbancia a la longitud de onda de 254 nm (21). Finalmente, se procedió a evaluar la recuperación de ciprofloxacina (1 ppt), a partir de cada muestra (M1-5), en las condiciones optimizadas.…”
Section: Determinación Electroquímica De Ciprofloxacinaunclassified
“…In recent years, solid phase extraction has been successfully used in sample pre-treatment technology (Albert et al, 2011;He & Blaney, 2015;Repizo et al, 2012; Rodríguez-González, González-Castro, Beceiro-González, Muniategui-Lorenzo, & PradaRodríguez, 2014). In this study solid phase extraction was chosen to purify the wine before detection.…”
Section: Optimization Of the Sample Preparationmentioning
confidence: 99%