2019
DOI: 10.1007/s00330-018-5947-4
|View full text |Cite|
|
Sign up to set email alerts
|

T1 mapping for liver function evaluation in gadoxetic acid–enhanced MR imaging: comparison of look-locker inversion recovery and B1 inhomogeneity–corrected variable flip angle method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
52
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 43 publications
(54 citation statements)
references
References 41 publications
2
52
0
Order By: Relevance
“…by using a variable flip angle approach, i.e. acquiring spoiled gradient echo images with different flip angles [97,98].…”
Section: Figure 57 Results From a Phantom Showing Correlation Betweementioning
confidence: 99%
See 2 more Smart Citations
“…by using a variable flip angle approach, i.e. acquiring spoiled gradient echo images with different flip angles [97,98].…”
Section: Figure 57 Results From a Phantom Showing Correlation Betweementioning
confidence: 99%
“…This could be a possible limitation to creating reliable biomarkers. An alternative strategy is to measure the actual T1 relaxation times, instead of arbitrary signal intensities [97,114,115]. Such a strategy could have the advantage of being less sensitive to differences in scanners, acquisition parameters, and different native T1 levels.…”
Section: Signal Intensity Ratiosmentioning
confidence: 99%
See 1 more Smart Citation
“…In our study, DWI or gadoxetic acid-enhanced sequences were additionally acquired in seven cases for planning imaging. These additional sequences are relatively time-consuming, especially since the time until a sufficient hepatobiliary phase for detection of small tumours is reached can significantly affect the procedure duration, as it depends on the hepatic function [ 27 ]. Nevertheless, these additional sequences can be relevant for detection and targeting of small tumours and can affect therapy decisions, as shown in our study where several new small metastases were detected in one patient using DWI during planning imaging.…”
Section: Discussionmentioning
confidence: 99%
“…MOLLI sequence was originally proposed for measuring T1 values of myocardium in cardiac imaging 13 . Since MOLLI can generate high resolution T1 maps in single breath-hold with good reproducibility, there have been several attempts to apply MOLLI sequence to obtain hepatic T1 maps in previous studies 8 , 14 , 15 . However, theses previous studies about hepatic T1 mapping using the MOLLI sequence have been conducted in adult patients with a breath-hold 5 , 8 , 16 .…”
Section: Introductionmentioning
confidence: 99%