1969
DOI: 10.1093/jaoac/52.3.458
|View full text |Cite
|
Sign up to set email alerts
|

Tar and Nicotine in Cigarette Smoke

Abstract: Cigarettes were conditioned 24 hr at 75°F and 60% relative humidity prior to being selected and smoked in a random order. Cigarettes were smoked in a Cambridge filter holder on an automatic smoking machine to a pre-determined butt length. TPM wet collection was on a CM113A filter disk and was determined as the net weight gain in the Cambridge filter holder after smoking. The filter pads were extracted with dioxane-isopropanol solution and were analyzed for moisture by gas chromatography. The pads and solvent e… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
43
0
1

Year Published

1970
1970
2010
2010

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 73 publications
(45 citation statements)
references
References 0 publications
1
43
0
1
Order By: Relevance
“…The environmental conditions during analysis (temperature and humidity), during the smoking process, the set-up and operational phases for the smoking machine were as described by the relevant ISO document: ISO 8243 (ISO, 2003) for sampling modalities at the sales point; ISO 3308 (ISO, 1991a) for analytical smoking conditions: temperature 22°C ± 2°C, humidity 60 ± 5% and air flow rate of 200 mm s −1 . Total particulate matter was collected on Cambridge filter pads (Pillsbury et al, 1969), which are efficient in trapping less volatile PAH aerosol that is present in cigarette smoke and represents the industry benchmark, but may not be as efficient in collecting the more volatile fractions. The Cerulean Smoking Machine used in the present study, belonging to British American Tobacco in Rome, Italy, was calibrated and used only for the routine analysis of mainstream smoke.…”
Section: Cerulean Asm 516 Smoking Machine (Sm)mentioning
confidence: 99%
“…The environmental conditions during analysis (temperature and humidity), during the smoking process, the set-up and operational phases for the smoking machine were as described by the relevant ISO document: ISO 8243 (ISO, 2003) for sampling modalities at the sales point; ISO 3308 (ISO, 1991a) for analytical smoking conditions: temperature 22°C ± 2°C, humidity 60 ± 5% and air flow rate of 200 mm s −1 . Total particulate matter was collected on Cambridge filter pads (Pillsbury et al, 1969), which are efficient in trapping less volatile PAH aerosol that is present in cigarette smoke and represents the industry benchmark, but may not be as efficient in collecting the more volatile fractions. The Cerulean Smoking Machine used in the present study, belonging to British American Tobacco in Rome, Italy, was calibrated and used only for the routine analysis of mainstream smoke.…”
Section: Cerulean Asm 516 Smoking Machine (Sm)mentioning
confidence: 99%
“…The environmental conditions for analysis (temperature and humidity) during the smoking process and the set-up and operational phases for the smoking machine were as described by the relevant ISO document: ISO 8243 (ISO, 2003) for sampling modalities at the sales point and ISO 3308 (ISO, 1991a) for analytical smoking conditions of 22 ± 2°C, 60 ± 5% humidity and an air flow rate of 200 mm s −1 . Total particulate matter was collected on Cambridge filter pads (Pillsbury et al, 1969), which are efficient for trapping less-volatile aerosol PAHs present in cigarette smoke and represent the industry benchmark but may not be as efficient for collecting the more volatile fractions. The Cerulean smoking machine used in the present study, belonging to Ente Tabacchi Italiano, Rome, Italy, was calibrated and used only for the routine analysis of mainstream smoke because for technical reasons we were not permitted to use the Cerulean smoking machine to collect sidestream smoke from our cigarettes.…”
Section: Cerulean Asm 516 Smoking Machinementioning
confidence: 99%
“…A modified ISO protocol with rectangular puff profile and free (open-end) smoking was used. In order to ensure TPM and 'tar' yields for reference cigarettes obtained under FTC conditions (Federal Trade Commission, 1967;Pillsbury et al, 1969); the air velocity around the 1R4F was kept lower than 10 mm s −1 . Controlled air flow at the cigarette level is necessary for effective removal of the sidestream smoke, which may otherwise falsify the mainstream smoke results, and to control the burning process of the cigarettes in accordance with standard smoking procedures.…”
Section: Smoke Generation With Conventional Research Cigarettesmentioning
confidence: 99%