Technical assessment of whole body angiography and cardiac function within a single MRI examination

Abstract: AimTo evaluate a combined protocol for simultaneous cardiac MRI (CMR) and contrast-enhanced (CE) whole-body MR angiography (WB-MRA) techniques within a single examination.Materials and methodsAsymptomatic volunteers (n = 48) with low-moderate risk of cardiovascular disease (CVD) were recruited. The protocol was divided into four sections: (1) CMR of left ventricle (LV) structure and function; (2) CE-MRA of the head, neck, and thorax followed by the distal lower limbs; (3) CMR LV “late gadolinium enhancement” a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

1
20
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 14 publications
(21 citation statements)
references
References 31 publications
1
20
0
Order By: Relevance
“…The MRI protocol has been described in detail elsewhere (15). In brief, imaging was performed using a 3-T Magnetom Trio Scanner (Siemens, Erlangen, Germany).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The MRI protocol has been described in detail elsewhere (15). In brief, imaging was performed using a 3-T Magnetom Trio Scanner (Siemens, Erlangen, Germany).…”
Section: Methodsmentioning
confidence: 99%
“…LV mass and volume quantification was performed as previously described (15). Values were normalized to height 1.7 .…”
Section: Methodsmentioning
confidence: 99%
“…From this, a “per decade” change in each variable was calculated, based on the assumption that the changes were linear with age. A formal assessment of intra‐ and interobserver repeatability has not been presented since this is reported elsewhere 22. However, reasonable estimates of interobserver variation can be extracted from the data generated by different segmentation observers because each of the respective cohorts were age‐matched, gender‐matched, and normalized to BSA.…”
Section: Methodsmentioning
confidence: 99%
“…The MR protocol has been described in detail elsewhere, 22 but in brief imaging was performed in the head-first supine orientation using a 3T [102x32] Scanner (Magnetom Trio, Siemens, Erlangen, Germany). A body matrix radiofrequency (RF) coil (six elements) was used in combination with a spine array (up to 24 elements).…”
Section: Methodsmentioning
confidence: 99%
“…18 In brief, the scans were performed on a 32 radio frequency (RF) receiver channel, 3-T MRI scanner (Magnetom ® Trio; Siemens, Erlangen, Germany). For whole-body coverage, a combination of six RF coils, including head matrix, neck matrix, spine matrix, 2 body matrices and peripheral angiography phased-array RF surface coils, were used.…”
Section: Methodsmentioning
confidence: 99%