2017
DOI: 10.1016/j.fusengdes.2017.01.023
|View full text |Cite
|
Sign up to set email alerts
|

Technical preparations for the in-vessel 14 MeV neutron calibration at JET

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 5 publications
0
5
0
Order By: Relevance
“…Another useful check is to compare the calculated and measured neutron rates. The total neutron rate from fusion reactions, including the thermal, beam-thermal, and beambeam fusion, is measured by the fission chambers at JET [6]. TRANSP calculates the synthetic neutron rate data with the given input profiles and Z eff with the NUBEAM module [22] using the following formula: For the DD discharges, pure deuterium fuel gas is assumed and the thermal ion density is n thermal,D = n e − ∑ j n imp,j Z imp,j and n thermal,T = 0 in equation (3).…”
Section: Data Consistencymentioning
confidence: 99%
See 1 more Smart Citation
“…Another useful check is to compare the calculated and measured neutron rates. The total neutron rate from fusion reactions, including the thermal, beam-thermal, and beambeam fusion, is measured by the fission chambers at JET [6]. TRANSP calculates the synthetic neutron rate data with the given input profiles and Z eff with the NUBEAM module [22] using the following formula: For the DD discharges, pure deuterium fuel gas is assumed and the thermal ion density is n thermal,D = n e − ∑ j n imp,j Z imp,j and n thermal,T = 0 in equation (3).…”
Section: Data Consistencymentioning
confidence: 99%
“…Hence, in preparation for the optimized ITER operation, it is necessary to demonstrate the transferability of the operation scenarios to the DT mixture plasmas in the ILW, and investigate the impact on the fusion performance. In addition, the 2020 JET-DTE2 will provide a good opportunity for study of isotope effects [5] and alpha particle physics, and the improvement of DT operation technology [6] such as tritium cycling, 14 MeV neutronics, remote handling, etc.…”
Section: Introductionmentioning
confidence: 99%
“…It can measure the distribution of particle number and size. According to the equivalent projection particle size, the light flux, which is blocked by particles, is received through the shading sensor and converted into electrical signals, which are transmitted to the counter through the preamplifier for counting. However, the trace free water suspended in jet fuel can also shield the light, which interferes with the results of the automatic particle counting method. …”
Section: Introductionmentioning
confidence: 99%
“…The constraints and early decisions which defined the main calibration approach, e.g. the RH compatibility and the limited space available, the technical requirements of the 14 MeV NG and the deployment method and the safety and engineering aspects have been discussed in a separate paper [5]. As the NG is not a stable neutron source, several monitoring detectors are attached to it by means of an ad hoc mechanical structure to continuously monitor the neutron emission rate and the total neutrons emitted during the in-vessel calibration.…”
Section: Introductionmentioning
confidence: 99%