Technische Mitteilung: Fehlplatzierter 13F-Shaldonkatheter in der A. subclavia – kontrollierte Entfernung mit einem unterdimensionierten 8F-Kollagen-Verschlusssystem (AngioSeal®) und endovaskulärer Ballonfixation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
3
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
2
2

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 0 publications
1
3
0
Order By: Relevance
“…7 Although successful hemostasis with an Angio-Seal™ device alone has been described in misplaced CVCs up to 11.5F size, several interventionalists prefer a balloon-supported insertion of Angio-Seal™ in the case of significant mismatch between the CVC and the 8F Angio-Seal to avoid dislocation of the anchor out of the vessel. 4,5,16 In the current study, closure of the arteriotomy site using an Angio-Seal™ was technically successful in all four cases in which there was no mismatch in size between the CVC and Angio-Seal™. Technical failure occurred in the one case in which the CVC with a size of approximately 11.5F was misplaced.…”
Section: Discussionsupporting
confidence: 53%
See 2 more Smart Citations
“…7 Although successful hemostasis with an Angio-Seal™ device alone has been described in misplaced CVCs up to 11.5F size, several interventionalists prefer a balloon-supported insertion of Angio-Seal™ in the case of significant mismatch between the CVC and the 8F Angio-Seal to avoid dislocation of the anchor out of the vessel. 4,5,16 In the current study, closure of the arteriotomy site using an Angio-Seal™ was technically successful in all four cases in which there was no mismatch in size between the CVC and Angio-Seal™. Technical failure occurred in the one case in which the CVC with a size of approximately 11.5F was misplaced.…”
Section: Discussionsupporting
confidence: 53%
“…This failure might have been caused by dislocation of the undersized anchor out of the vessel and consequent extravascular placement of the Angio-Seal™. Therefore, in the case of a mismatch in diameter of the Angio-Seal™ and CVC, it might be beneficial to remove large-bore CVCs in a balloon-supported manner, as described by Bovenschulte et al 5 or at least to be prepared to perform a temporary balloon tamponade until successful closure (e.g. by stent placement) of the arteriotomy site.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The database search returned 382 results out of which 32 studies [ 3 , 6 35 ] were eligible for inclusion in this review (Fig. 2 ) with a total of 69 patients having being studied (Table 1 ).…”
Section: Resultsmentioning