2012
DOI: 10.1016/j.renene.2012.02.029
|View full text |Cite
|
Sign up to set email alerts
|

Techno-economic simulation and optimization of residential grid-connected PV system for the Queensland climate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
52
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 145 publications
(52 citation statements)
references
References 15 publications
0
52
0
Order By: Relevance
“…These values were calculated using a previous reference, which is a report issued in 2011 by the Intergovernmental Panel on Climate Change (IPCC) [32]. In the previous research, the annual O&M costs of PV panels were assumed to be approaching 0 [33]. We also assumed the lifetime of a PV array as 25 years.…”
Section: Renewable Energy Generation Systemsmentioning
confidence: 99%
See 2 more Smart Citations
“…These values were calculated using a previous reference, which is a report issued in 2011 by the Intergovernmental Panel on Climate Change (IPCC) [32]. In the previous research, the annual O&M costs of PV panels were assumed to be approaching 0 [33]. We also assumed the lifetime of a PV array as 25 years.…”
Section: Renewable Energy Generation Systemsmentioning
confidence: 99%
“…Batteries are the most difficult component to model. Thus, we use sensitivity analysis to select both the Surrette 6CS25P battery (6.94 kWh) (Rolls/Surrette, Springhill, NS, Canada) and the Hoppecke 20 OpzS2500 battery (5 KWh) (Hoppecke, New Jersey, NY, USA), which are widely used for hybrid energy system analysis in this study, as a storage system to analyze and simulate the optimal hybrid energy system [33,[35][36][37].…”
Section: Renewable Energy Generation Systemsmentioning
confidence: 99%
See 1 more Smart Citation
“…Long term assessments for grid connect PV systems for residential power generation were conducted for eleven main cities in Queensland-Australia using a computer simulation [6]. The impact of PV panel slope on energy fed to grid, investment cost, financial income, and CO 2 emission were also studied.…”
Section: Introductionmentioning
confidence: 99%
“…Nevertheless, Liu [8,9] has performed a system optimization for using PV and battery to power residential buildings in Queensland, and finds that, 6 kW roof-mounted panels with an angle of 20-25 degrees can provide nearly two-thirds of the electricity requirements.…”
mentioning
confidence: 99%