2020
DOI: 10.1016/j.mri.2020.07.010
|View full text |Cite
|
Sign up to set email alerts
|

Test-retest reliability and reproducibility of long-label pseudo-continuous arterial spin labeling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
19
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 16 publications
(19 citation statements)
references
References 24 publications
0
19
0
Order By: Relevance
“…This software processes pcASL data in a standardized one-click mode. The same model used for CBF calculation was based on a previous study (Williams et al, 1992 ; Lin et al, 2020 ). Data were preprocessed using SPM12 (Wellcome Department of Cognitive Neurology, Institute of Neurology, London, United Kingdom) implemented on MATLAB (MathWorks, Natick, MA, United States).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…This software processes pcASL data in a standardized one-click mode. The same model used for CBF calculation was based on a previous study (Williams et al, 1992 ; Lin et al, 2020 ). Data were preprocessed using SPM12 (Wellcome Department of Cognitive Neurology, Institute of Neurology, London, United Kingdom) implemented on MATLAB (MathWorks, Natick, MA, United States).…”
Section: Methodsmentioning
confidence: 99%
“…This software processes pcASL data in a standardized one-click mode. The same model used for CBF calculation was based on a previous study (Williams et al, 1992;Lin et al, 2020 Natick, MA, United States). First, the CBF maps were coregistered to 3D T1-weighted images.…”
Section: Asl Data Processmentioning
confidence: 99%
“…96 Multiple studies have demonstrated good feasibility, applicability and reproducibility of ASL in geriatric populations. 71,97 The clinical application of 'classical' ASL imaging is still limited though.…”
Section: Recent Technical Advances Expanding the Clinical Use Of Asl ...mentioning
confidence: 99%
“…Betweensubjects, the pCASL CBF measurements in the post-surgical pain state and CBF were both characterized as moderately reliable (ICC > 0.4) across nine ROIs. Lin et al (2020) compared test-retest repeatability of 3D pCASL with standard (1,500 ms) and long (3,500 ms) labeling duration in 20 adult volunteers (age 56.6 ± 17.2 years) with a 1 h interval. The ICCs were generally high (> 0.85) and wsCV < 10% across lobar ROIs with the long labeling duration pCASL showing higher repeatability.…”
Section: Test-retest Repeatability Of Cbfmentioning
confidence: 99%