2003
DOI: 10.1590/s1517-86922003000500007
|View full text |Cite
|
Sign up to set email alerts
|

Testes de força e resistência muscular: confiabilidade e predição de uma repetição máxima - Revisão e novas evidências

Abstract: A confiabilidade intra-avaliadores é fundamental na determinação da qualidade dos dados coletados em uma pesquisa. Poucos estudos controlados têm reportado valores de confiabilidade de testes de força e, apesar de esta ser considerada boa na maioria dos estudos publicados (0,79 a 0,99), as diferenças entre teste e reteste têm sido observadas como estatisticamente significativas. Dessa forma, sugere-se a utilização dos valores de um segundo teste, pelo menos, em estudos de pesquisa, de modo que eventuais modifi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
31
1
33

Year Published

2007
2007
2024
2024

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 78 publications
(65 citation statements)
references
References 26 publications
0
31
1
33
Order By: Relevance
“…Resistance tests have their main application in the scientific investigation in the cases where it is necessary to understand the capacity of the individuals in generating tension (9) . Isokinetic dynamometry, gold standard for muscular strength evaluation, provides reliable values on the generated torque and subsequently, the force ratio between flexors and extensors (5) .…”
Section: Introductionmentioning
confidence: 99%
“…Resistance tests have their main application in the scientific investigation in the cases where it is necessary to understand the capacity of the individuals in generating tension (9) . Isokinetic dynamometry, gold standard for muscular strength evaluation, provides reliable values on the generated torque and subsequently, the force ratio between flexors and extensors (5) .…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, no statistically significant difference was verified in the comparison between the mean values obtained in 1-RM tests and the mean values estimated by the Brzycki equation from the application of submaximal tests of 7-10 RM (t = 0.47; P > 0.05). These results are very interesting, once the estimation of 1RM from these submaximal tests usually present correlation values fairly high (r > 0.90), the ESE reported in the majority of the studies has been higher or equal to 10% (12) .…”
Section: Workload Lifted Testsmentioning
confidence: 72%
“…The 10 repetition maximum test (10RM) application was chosen for presenting high correlation with the muscle strength assessed in 1RM (14) . The test was applied in alternation by segment in the following order: leg press 45º, bench press, leg extension and biceps curl.…”
Section: Muscle Strength Evaluation In 10rmmentioning
confidence: 99%