2013
DOI: 10.1093/annhyg/met060
|View full text |Cite
|
Sign up to set email alerts
|

Testing of Glove Efficacy against Sprayed Isocyanate Coatings Utilizing a Reciprocating Permeation Panel

Abstract: The permeation panel II is a reliable method to assess dermal protective clothing performance against polymerizing coatings. Commonly used 5-mil (0.13-mm) latex and nitrile gloves were determined to be ineffective barriers against the isocyanates found in a commonly used clear-coat formulation while butyl gloves were protective.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

0
1
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(1 citation statement)
references
References 19 publications
0
1
0
Order By: Relevance
“…Provide nitrile or other appropriate chemical resistant gloves for use in each bay. Latex gloves should not be used because they are not protective against isocyanate paints and can cause allergic reactions in sensitive individuals [Ceballos et al 2014]. …”
mentioning
confidence: 99%
“…Provide nitrile or other appropriate chemical resistant gloves for use in each bay. Latex gloves should not be used because they are not protective against isocyanate paints and can cause allergic reactions in sensitive individuals [Ceballos et al 2014]. …”