2006
DOI: 10.5005/jp/books/10919
|View full text |Cite
|
Sign up to set email alerts
|

Textbook of Medical Laboratory Technology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
34
0

Year Published

2010
2010
2019
2019

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 36 publications
(34 citation statements)
references
References 0 publications
0
34
0
Order By: Relevance
“…In the present study, creatinine and uric acid determinations were critical as markers of kidney function (Newman and Price, 1999). Creatinine is excreted out of the body entirely by the kidneys while uric acid is excreted to a large degree by the kidneys and to a smaller degree in the intestinal tract by microbial degradation (Sood, 2006). Elevated creatinine and uric acid levels in the serum of untreated diabetic rats signify impaired kidney function or disease (Sood, 2006).…”
Section: Discussionmentioning
confidence: 99%
“…In the present study, creatinine and uric acid determinations were critical as markers of kidney function (Newman and Price, 1999). Creatinine is excreted out of the body entirely by the kidneys while uric acid is excreted to a large degree by the kidneys and to a smaller degree in the intestinal tract by microbial degradation (Sood, 2006). Elevated creatinine and uric acid levels in the serum of untreated diabetic rats signify impaired kidney function or disease (Sood, 2006).…”
Section: Discussionmentioning
confidence: 99%
“…The total numbers of sperms were counted in the 5 major squares on each side of the haemocytometer and determined the average for calculating sperm count. [9] The haemocytometer is 0.1mm deep and the 25 large squares represent an area of 1 square millimeter with a volume of 0.1 µl. When 5 squares are counted, the sperms which are settled out of 0.02 µl only are counted.…”
Section: Sperm Countmentioning
confidence: 99%
“…The blood was allowed to clot at room temperature which helps the plasma separate from cells and after two hours serum was separated from blood by centrifuging at 3000 rpm for 10 minutes. The extracted serum was immediately transferred to a plastic vial and stored at -20° C in deep freezer, 13 at Blood Bank Unite of Nanakaly Hospital for Blood Diseases. Sera were testes for TNF-α by enzyme-linked immunosorbent assay (ELISA) according to the manufacturer instruction kit (Koma Biotech INC Human TNF-α /ELISA Kit: Cat# K0331131 U.S.A.) at Virology Unite of the Nanakaly Hospital for Blood Diseases.…”
Section: Stent Preparationmentioning
confidence: 99%