2020
DOI: 10.2967/jnmt.120.246157
|View full text |Cite
|
Sign up to set email alerts
|

Texture Feature Comparison Between Step-and-Shoot and Continuous-Bed-Motion 18F-FDG PET

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 25 publications
0
3
0
Order By: Relevance
“…The similar high reproducibility of PCA‐based DDG‐PET and SAM‐based DDG‐PET suggests the potential for interchangeability of texture features between other DDG‐PET methods and NG‐PET. In contrast, some texture features associated with GLRLM and GLZLM were not reproducible because these matrix indices, which are known to be highly variable, are calculated from large scales with many voxels 39,40 . In other words, non‐reproducible features are thought to be affected by blurring reduction due to the application of DDG.…”
Section: Discussionmentioning
confidence: 97%
See 1 more Smart Citation
“…The similar high reproducibility of PCA‐based DDG‐PET and SAM‐based DDG‐PET suggests the potential for interchangeability of texture features between other DDG‐PET methods and NG‐PET. In contrast, some texture features associated with GLRLM and GLZLM were not reproducible because these matrix indices, which are known to be highly variable, are calculated from large scales with many voxels 39,40 . In other words, non‐reproducible features are thought to be affected by blurring reduction due to the application of DDG.…”
Section: Discussionmentioning
confidence: 97%
“…In contrast, some texture features associated with GLRLM and GLZLM were not reproducible because these matrix indices, which are known to be highly variable, are calculated from large scales with many voxels. 39,40 In other words, non-reproducible features are thought to be affected by blurring reduction due to the application of DDG. From a different perspective, reproducibility confirmed in useful texture features such as GLCM Entropy and GLCM Dissimilarity is important.…”
Section: Discussionmentioning
confidence: 99%
“…In contrast to our reproducibility study, only a small fraction of radiomics features was considered as stable because radiomics features had varying values between the different respiratory patterns. Yamashita et al ( 2021 ) only looked at texture features derived from step-and-shoot and continuous bed motion [ 18 F]-FDG PET/CT. To see the influence between the two acquisitions, the mean difference percentage and correlation coefficient between the two derivations of radiomics features were calculated.…”
Section: Discussionmentioning
confidence: 99%