1999
DOI: 10.1016/s0169-2607(99)00017-6
|View full text |Cite
|
Sign up to set email alerts
|

The analysis of heart rate variability in unrestrained rats. Validation of method and results

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

9
126
0
5

Year Published

2004
2004
2019
2019

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 144 publications
(140 citation statements)
references
References 16 publications
9
126
0
5
Order By: Relevance
“…Premature supraventricular and ventricular beats, missed beats and pauses that could affect the result of spectral analysis were filtered and replaced by an interpolated value according to a cubic spline function curve fitting. 27,28 The spectra of HRV were expressed as low-frequency (LF: 0.05-0.2 Hz) and high-frequency (HF: 0.2-1.0 Hz) components. The power (ms 2 ) of LF and HF was calculated at 1-min intervals, and the HF and LF/HF ratio were used as indexes of parasympathetic and sympathetic nervous activities, respectively.…”
Section: Discussionmentioning
confidence: 99%
“…Premature supraventricular and ventricular beats, missed beats and pauses that could affect the result of spectral analysis were filtered and replaced by an interpolated value according to a cubic spline function curve fitting. 27,28 The spectra of HRV were expressed as low-frequency (LF: 0.05-0.2 Hz) and high-frequency (HF: 0.2-1.0 Hz) components. The power (ms 2 ) of LF and HF was calculated at 1-min intervals, and the HF and LF/HF ratio were used as indexes of parasympathetic and sympathetic nervous activities, respectively.…”
Section: Discussionmentioning
confidence: 99%
“…22 Premature supraventricular and ventricular beats, missed beats and pauses were filtered and replaced by an interpolated value. Subsequent analysis was performed using methods published previously by Aubert et al 23 Power spectral analysis of HRV was performed by Fast Fourier Transform algorithm. Power spectral analysis allowed estimating the power in the low frequency (LF) and in the high frequency (HF) range.…”
Section: Signal Processingmentioning
confidence: 99%
“…A análise da VFC em roedores reflete um mecanismo de regulação cardiovascular semelhante a humanos, porém o tônus vagal ausente ou baixo em repouso nos roedores pode alterar a qualidade e grau da resposta da VFC após as exposições (Japundzic et al, 1990;Cerutti et al, 1991;Kuwahara et al, 1994;Aubert et al, 1999). Estas diferenças podem portando significar que não há necessariamente uma similaridade nos desfechos, e que o valor prognóstico da VFC que é demonstrado em diversas patologias humanas, ainda é prematuro para uso em roedores como um indicador de prognostico negativo ou toxicidade após exposições a poluentes ambientais (Rowan III et al, 2007).…”
Section: Discussionunclassified