2019
DOI: 10.3390/s19133004
|View full text |Cite
|
Sign up to set email alerts
|

The Analysis of the Urea Biosensors Using Different Sensing Matrices via Wireless Measurement System & Microfluidic Measurement System

Abstract: Two types of urea biosensors were integrated with a wireless measurement system and microfluidic measurement system. The two biosensors used were (i) a magnetic beads (MBs)-urease/graphene oxide (GO)/titanium dioxide (TiO2)-based biosensor and (ii) an MBs-urease/GO/ nickel oxide (NiO)-based biosensor, respectively. The wireless measurement system work exhibited the feasibility for the remote detection of urea, but it will require refinement and modification to improve stability and precision. The microchannel … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2019
2019
2025
2025

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 18 publications
(11 citation statements)
references
References 30 publications
0
11
0
Order By: Relevance
“…In this chemical equation, urea reacts with urease and is converted to ammonium (NH4 + ), bicarbonate (HCO 3 − ), and hydroxide ions (OH − ) [25]. The sensing properties of the flexible arrayed RuO 2 urea biosensor were measured by the V–T measurement system.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…In this chemical equation, urea reacts with urease and is converted to ammonium (NH4 + ), bicarbonate (HCO 3 − ), and hydroxide ions (OH − ) [25]. The sensing properties of the flexible arrayed RuO 2 urea biosensor were measured by the V–T measurement system.…”
Section: Resultsmentioning
confidence: 99%
“…Next, the RuO 2 film was deposited on the flexible arrayed PET substrate through a sputtering system to form the RuO 2 film window; then, it was encapsulated with an epoxy thermosetting polymer. The urease was immobilized because of the covalent bond, its low diffusivity, and strong binding, which reduced the loss and stability of the urease [25]. Afterward, the aminopropyltriethoxysilane (APTS) solution was dropped on the RuO 2 sensing film at room temperature.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The main advantages of the instrumentation are that they do not require a reference electrode, are inexpensive, have the ability to minimize the direct electrical response, are fast, and are single-use biological devices [90][91][92]. In this study, urease based magnetic beads were modified with graphene oxide and nickel oxide to have conduction of interfacial electrons and high enzyme binding activity [93]. Upon the target outline in urea samples, the wireless measurement system and the microfluidic measurement system proceeded to separate testing assays.…”
Section: Conductometric Biosensing Devicesmentioning
confidence: 99%