2007
DOI: 10.1002/rcm.3255
|View full text |Cite
|
Sign up to set email alerts
|

The combined use of thermal desorption and selected ion flow tube mass spectrometry for the quantification of xylene and toluene in air

Abstract: Thermal desorption (TD) is commonly employed for volatile chemical analysis, it being the method of choice for occupational health and safety monitoring. TD allows for offline capture of volatiles onto a solid sorbent followed by desorption and analysis at a later time. Although TD is routinely used in conjunction with gas chromatography (TD-GC), the assay throughput is low and requires the use of gas standards for quantification. Another technique increasingly employed for volatile chemical analysis, selected… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
24
0

Year Published

2008
2008
2021
2021

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 27 publications
(24 citation statements)
references
References 13 publications
0
24
0
Order By: Relevance
“…This ATD/ SIFT-MS combination not only provides rapid analysis, but the effective preconcentration of trace gases from the sample ultimately lowers their limit of detection to sub-ppb levels. Using standard samples the linearity of this system has been demonstrated within the concentration range from 1 to 10 ppb (Ross & Vermeulen, 2007). Hryniuk and Ross (2009) have now successfully used this ATD/SIFT-MS combination for breath analysis and found that there was a 1 to 1 concordance between the levels of isoprene and acetone in the breath of 12 healthy volunteers as measured using this combination technique and direct real-time SIFT-MS measurements.…”
Section: Recent Extensions To Sift-msmentioning
confidence: 94%
See 2 more Smart Citations
“…This ATD/ SIFT-MS combination not only provides rapid analysis, but the effective preconcentration of trace gases from the sample ultimately lowers their limit of detection to sub-ppb levels. Using standard samples the linearity of this system has been demonstrated within the concentration range from 1 to 10 ppb (Ross & Vermeulen, 2007). Hryniuk and Ross (2009) have now successfully used this ATD/SIFT-MS combination for breath analysis and found that there was a 1 to 1 concordance between the levels of isoprene and acetone in the breath of 12 healthy volunteers as measured using this combination technique and direct real-time SIFT-MS measurements.…”
Section: Recent Extensions To Sift-msmentioning
confidence: 94%
“…The performance of Profile 3 SIFT-MS instruments has been illustrated by the data presented in several research papers produced by the teams at Keele , 2009Smith et al, 2008;Wang et al, 2008a;Wang, Š paněl, & Smith, 2008b;, at Prague (Španěl, Dryahina, & Smith, 2007a,b,c) and at Thunder Bay (Ross & Vermeulen, 2007;Ross, 2008;Hryniuk & Ross, 2009;Ross, Babay, & Ladouceur, 2009;). Scrutiny of these papers reveals the value and the quality of trace gas analyses obtained using current Profile 3 instruments.…”
Section: Performance Of the Profile 3 Instrumentmentioning
confidence: 98%
See 1 more Smart Citation
“…Experiments using a mixture of Carbograph 2 and Carbograph 5 also showed low breakthrough volumes (<1%) for a number of VOCs, including o-xylene [201]. Ross and Vermeulen [198] observed good correlation between the amount of toluene and xylene applied to tubes containing Carbograph 1TD (one of the adsorbents in our multi-sorbent bed) and the amount measured after thermally desorbing the tubes. Artifact build-up during storage has been reported when using single sorbent tubes.…”
Section: Resultsmentioning
confidence: 59%
“…However, it is not always possible to bring the source of volatiles and the analytical device together. To circumvent this problem, volatile storage containers can be used such as Teflon or Tedlar bags ( [191]; [192]; [193]), canisters ( [194]; [195]), and Tenax TA or Carbotrap/Carbograph thermodesorption tubes ( [196]; [197]; [198]; [199]). Thermo desorption tubes trap different groups of volatiles depending on the sorbent placed inside the tubes, either by diffusion or by pumping the gas through the tube.…”
Section: Introductionmentioning
confidence: 99%