1989
DOI: 10.1007/bf01646870
|View full text |Cite
|
Sign up to set email alerts
|

The composition of anal basal pressure

Abstract: The maximal anal basal pressure (MABP) was measured with probes of 0.3, 1, 2 and 3 cm diameter in 21 subjects, 60 years old, without anal pathology. The components of MABP were analyzed by inducing a maximal internal sphincter (IS) relaxation, taking pressure measurements in the conscious state and during narcosis with curarization. In seven cases pressure measurements were done on isolated anorectum after abdominoperineal rectum amputation. MABP increases with probe diameter before as well as during anaesthes… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
38
0

Year Published

1990
1990
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 286 publications
(39 citation statements)
references
References 23 publications
1
38
0
Order By: Relevance
“…The ability of the anal cushions to alter their volume through their vascular component allows for both the preservation of continence and the passage of stool. Vascular filling is thought to contribute between 15 and 20% of resting anal pressure [8]. …”
Section: Aetiology and Classificationmentioning
confidence: 99%
“…The ability of the anal cushions to alter their volume through their vascular component allows for both the preservation of continence and the passage of stool. Vascular filling is thought to contribute between 15 and 20% of resting anal pressure [8]. …”
Section: Aetiology and Classificationmentioning
confidence: 99%
“…Most of these were developed to detect pressure and changes in pressure. Measurement of CA has only been vaguely studied [9,10] and not during dynamic distension as in this study.…”
Section: Methodological Aspectsmentioning
confidence: 99%
“…Mea surement of pressure-CA relations in the anal-sphincter region may enhance our knowledge of the continence and defecation mechanism in physiological and diseased states. Until now anal wall properties during distension have only been vaguely studied using rigid plastic probes [9,10], partly be cause no method existed to measure it [15].…”
mentioning
confidence: 99%
“…The most commonly used parameters in conventional anal manometry are the resting anal pressure and the maximum anal pressure following a voluntary squeeze effort [7][8][9]. In conventional anal manometry, where micro-balloons are used, these pressures comprise the mathematic circumferential mean of all the pressures of the anal canal surface touching the balloon.…”
Section: Introductionmentioning
confidence: 99%